PB-600 Instruction Manual
PB-600 Instruction Manual 1.Front and back panel ON/OFF SWITCH AC INLET ON Fan Ventilation Hole OFF AC INPUT Figure 1.1 Front Panel LED Indicator Battery Positive Common Negative + - Power 8 Stage 2 Stage 2/8 stage selection switch Function Connector 1 3 5 7 9 2 4 6 8 10 1 3 5 7 9 2 4 6 8 10 Battery WARNING : Please check battery polarity before connection Figure 1.2 Back Panel Assembly Guidelines: 1.The charger should be turned OFF prior to battery connection.
2.Derating Curves 2.1 Charging current VS Temperature 100 80 LOAD (%) 60 40 20 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE ( ) 3.Function Description of CN100 Pin No. Function Description 1,2 RY13 5,6 RY15 Relay contact rating(max.) : 30V/1A resistive. ; "Short" when the battery is full, "Open" when the battery is still charging Relay contact rating(max.) : 30V/1A resistive.
5.2 "8" stage charging (Selection switch to "8" stage) Advantage of pulse stage: Use pulse current to revive aged battery. Advantage of recond stage: Allow full charge of battery. Advantage of Float and Maintain stage: After LED turns green, maintenance charge is provided so the battery is always in a full state. User will have access to a full battery whenever it is disconnected from the charger.
6.3 Charger OK Relay(RY15) CN100 Between pin5 and pin6 Charger Normal work ON (Short) Failure or the protection function is activating OFF(Open) 1 RY13 RY13 2 NC NC RY15 RY15 GND RTH 9 RC- RC+ 10 RY15 6.4 Output OK Relay(RY13) CN100 1.Bank OK (RY13) 1 Between pin1 and pin2 Bank Color of LED RY13 RY13 NC NC Battery Full ON (Short) Green RY15 RY15 Charging OFF(Open) Orange GND RTH 9 2 RC- RC+ 10 RY13 6.
2. If you're unsure about max allowable charging current of the battery, please refer to the battery's technical specification or consult its manufacturer. 9.Suggested the number of cells Model Number Battery capacity PB-600-12 PB-600-24 100AH 80AH 1~4 1~3 PB-600-48 46AH 1~2 10.Series and parallel connection of batteries 1.Batteries in series Voltage can be doubled when 2 batteries are connected in series. However, the capacity (AH) will remain the same.