Datasheet
SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDTIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGHUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
1000ms,20ms/230VAC1000ms,20ms/115VACatfullload
100ms/230VAC24ms/115VACatfullload
85~264VAC120~370VDC
47~440Hz
71%67% 73%
13.8~16.2V
74%
17.25~20.25V
76%
27.6~32.4V
0.12A/115VAC0.08A/230VAC
COLDSTART 25A/115VAC45A/230VAC
Above105% ratedoutputpower
5.75~6.75V3.8~4.95V
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
I/P-O/P:4KVAC
I/P-O/P:100MOhms/500VDC
20~90%RHnon-condensing
-20~+70 (Refertooutputloadderatingcurve)
-40~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,2G10min./1cycle,Periodfor60min.eachalongX, Y,Zaxes
1513.4Khrsmin.MIL-HDBK-217F(25 )
62.85*50*19.7mm(L*W*H)
0.085Kg;120pcs/11.2Kg/0.97CUFT
FileName:PM-05-SPEC2006-04-07
0.5%
1.0%
0.5%
1.0%
0.5%
0.5%
1.0%
1.0%
1.0%
1.0%
2.0% 2.0% 2.0% 2.0%3.0%
80mVp-p80mVp-p 150mVp-p 150mVp-p 240mVp-p
5V3.3V 12V 15V 24V
1A1.25A 0.42A 0.33A 0.23A
0~1A0~1.25A 0~0.42A 0~0.33A 0~0.23A
5W4.125W 5.04W 4.95W 5.52W
PM-05-5 PM-05-12 PM-05-15 PM-05-24PM-05-3.3
SAFETY STANDARDS
UL60601-1,TUVEN60601-1 Approved
5WOutputSwitchingPowerSupply
PM-05 series
Features :
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
EMICONDUCTION&RADIATION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
Protectiontype:Shutoff
CompliancetoEN55011 ,EN55022(CISPR22)ClassB(CISPR11)
HARMONICCURRENT
EMSIMMUNITY
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,EN60601-1-2,EN61204-3Medicallevel,criteria A
IEC60601-1
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Ultra-miniature size, light weight
Cooling by free air convection
Isolation class
UL60601-1/IEC60601-1/EN60601-1 medical safety approved
No load power consumption<0.5W
100% full load burn-in test
Fixed switching frequency at 67KHz
High reliability
3 years warranty