Datasheet

SPECIFICATION
PS-65-3.3 PS-65-5 PS-65-7.5 PS-65-12 PS-65-13.5 PS-65-15 PS-65-24 PS-65-27 PS-65-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
ACCURRENT (Typ.)
3.3V
5V 7.5V 12V 13.5V 15V 24V 27V 48V
12A 12A 8A 5.2A 4.7A 4.2A 2.7A 2.4A 1.35A
0~15.2A 0~13.8A 0~9.6A 0~6A 0~5.4A 0~4.8A 0~3A 0~2.7A 0~1.5A
39.6W 60W 60W 62.4W 63.45W 63W 64.8W 64.8W 64.8W
80mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
3.14~3.63V 4.75~5.5V 7.13~8.25V 11.4~13.2V 12.8~14.9V
14.25~16.5V
22.8~26.4V
25.65~29.7V
45.6~52.8V
3.0% 3.0% 3.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0%
1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
3.0% 3.0% 3.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0%
800ms,20msatfullload
60msatfullload
90~264VAC127~370VDC
47~440Hz
69% 76% 79% 79% 79% 79% 80% 80% 80%
1.2A/115VAC0.72A/230VAC
COLDSTART 20A/115VAC40A/230VAC
<0.75mA /240VAC
73~105W(3.3V:51~75W)(5V:70~105W) ratedoutputpower
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
-10~+60 (Referto"DeratingCurve")
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.04%/ (0~50
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
300.7Khrsmin.MIL-HDBK-217F(25 )
127*76*42mm(L*W*H)
0.21Kg;54pcs/14.2Kg/1.35CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Heat Sink HS1,HS2 can not be shorted.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
FileName:PS-65-SPEC 2013-02-23
OVERVOLTAGE
SAFETY STANDARDS
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024,lightindustrylevel,criteria A
65WSingleOutputSwitchingPowerSupply
PS-65 se ri es
Features :
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:2KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
Universal AC input/Full range
Low leakage current<0.75mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
Ratedoutputpowerforconvection;72W(+3.3V:50W;+5V:69W)with18CFMmin.ForcedairOUTPUTPOWER(max.)
3.8~4.46V 5.75~6.75V 8.63~10.1V 13.8~16.2V 15.5~18.2V
17.25~20.25V
27.6~32.4V 31~36.45V
55.2~64.8V
EMCIMMUNITY
EMCEMISSION

Summary of content (2 pages)