SPECIFICATION
PS-65-3.3 PS-65-5 PS-65-7.5 PS-65-12 PS-65-13.5 PS-65-15 PS-65-24 PS-65-27 PS-65-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
ACCURRENT (Typ.)
3.3V
5V 7.5V 12V 13.5V 15V 24V 27V 48V
12A 12A 8A 5.2A 4.7A 4.2A 2.7A 2.4A 1.35A
0~15.2A 0~13.8A 0~9.6A 0~6A 0~5.4A 0~4.8A 0~3A 0~2.7A 0~1.5A
39.6W 60W 60W 62.4W 63.5W 63W 64.8W 64.8W 64.8W
80mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
3.14~3.63V 4.75~5.5V 7.13~8.25V 11.4~13.2V 12.8~14.9V
14.25~16.5V
22.8~26.4V
25.65~29.7V
45.6~52.8V
3.0% 3.0% 3.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0%
1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
3.0% 3.0% 3.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0%
800ms,20msatfullload
60msatfullload
90~264VAC127~370VDC
47~440Hz
69% 76% 79% 79% 79% 79% 80% 80% 80%
1.2A/115VAC0.72A/230VAC
COLDSTART 20A/115VAC40A/230VAC
<0.75mA /240VAC
73~105W(3.3V:51~75W)(5V:70~105W) ratedoutputpower
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
-10~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.04%/ (0~50
10~500Hz,2G10min./1cycle,Periodfor60min.eachalongX, Y,Zaxes
300.7Khrsmin.MIL-HDBK-217F(25 )
127*76*42mm(L*W*H)
0.21Kg;54pcs/14.2Kg/1.35CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
FileName:PS-65-SPEC 2007-03-14
OVERVOLTAGE
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
UL60950-1, TUVEN60950-1 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,Lightindustrylevel,criteria A
65WSingleOutputSwitchingPowerSupply
PS-65 se ri es
Features :
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
EMICONDUCTION&RADIATION
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
Universal AC input/Full range
Low leakage current<0.5mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
Ratedoutputpowerforconvection;72W(+3.3V:50W;+5V:69W)with18CFMmin.ForcedairOUTPUTPOWER(max.)
3.8~4.46V 5.75~6.75V 8.63~10.1V 13.8~16.2V 15.5~18.2V
17.25~20.25V
27.6~32.4V 31~36.45V
55.2~64.8V