Datasheet
SPECIFICATION
PT-65A PT-65B PT-65C PT-65D
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
ACCURRENT (Typ.)
5V 12V
CH2
-5V
CH3 CH1
12V
CH2
-12V
CH3
5V
CH1
15V
CH2
-15V
CH3
5V
CH1
12V
CH2
24V
CH3
5.5A 2.5A 0.5A 5.5A 2.5A 0.5A 5.5A 0.5A 4A 2A 1A
0.4~7A 0.2~3.2A 0~0.7A 0.4~7A 0.2~3.2A 0~0.7A 0.4~7A 0.2~2.6A 0~0.7A 0.5~5A 0.2~4A 0.2~1.3A
60W 63.5W 65W 68W
50mVp-p 120mVp-p 50mVp-p 50mVp-p 120mVp-p 100mVp-p 50mVp-p 120mVp-p 100mVp-p 50mVp-p 100mVp-p 200mVp-p
CH1:4.75~5.5V
4.0% 7.0% 5.0% 4.0% 7.0% 5.0% 4.0% 7.0% 5.0% 4.0% 6.0% 6.0%
1.0% 2.0% 1.0%
1.0%
1.0% 2.0% 1.0% 1.0% 2.0% 1.0% 1.0% 2.0% 3.0%
3.0% 4.0% 3.0% 4.0% 1.0% 3.0% 4.0% 1.0% 2.0% 5.0% 5.0%
800ms,20msatfullload
60msatfullload
90~264VAC127~370VDC
47~440Hz
76% 77% 77% 79%
1.5A/115VAC0.9A/230VAC
COLDSTART 20A/115VAC40A/230VAC
<0.75mA
73~95W ratedoutputpower 74.8~98.6W ratedoutputpower
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
-10~+60
(Referto"DeratingCurve")
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.04%/ (0~50 )on+5Voutput
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
277.2Khrsmin.MIL-HDBK-217F(25 )
127*76*42mm(L*W*H)
0.25Kg;54pcs/15.9Kg/1.35CUFT
FileName:PT-65-SPEC 2011-09-30
5.75~6.75VDConCH1
OVERVOLTAGE
SAFETY STANDARDS
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
Complianceto EN55024,lightindustrylevel,criteria AEN61000-4-2,3,4,5,6,8,11,
65W TripleOutputSwitchingPowerSupply
Features :
PT-65 se ri es
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC1min.
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Heat Sink HS1,HS2 can not be shorted.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Universal AC input/Full range
Low leakage current<0.5mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
OUTPUTPOWER(max.) Ratedoutputpowerforconvection;72Wwith18CFMmin.Forcedair
CH1
OUTPUTNUMBER
5V
2A
EMCIMMUNITY
EMCEMISSION