Datasheet

90W PWM output LED power supply
PWM-90 series
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
SETUP, RISE TIME Note.2
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
SHORT CIRCUIT
OVER TEMPERATURE
12V 24V 36V 48V
7.5A 3.75A 2.5A 1.88A
90W 90W 90W 90.24W
0 ~ 100%
300Hz
±4.0% ±3.0% ±2.0% ±1.0%
500ms, 80ms 115VAC / 230VAC at full load
16ms/230VAC 16ms/115VAC at full load
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
88% 90.5% 90.5% 90.5%
<0.25mA / 277VAC
108 ~ 120% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
224.2K hrs min. MIL-HDBK-217F (25)
171*63*37.5mm (L*W*H)


0.77Kg; 18pcs/14.9Kg/0.82CUFT
DIMMING RANGE
PWM FREQUENCY (Typ.)
VOLTAGE TOLERANCE
ENVIRONMENT
SAFETY &
EMC
PROTECTION
15 ~ 17V 28 ~ 34V 41 ~ 46V 54 ~ 60V
0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC
PWM-90-12 PWM-90-24 PWM-90-36 PWM-90-48
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
EMC IMMUNITY
Compliance to EN55015, EN61000-3-2 Class C (60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge L- N : 2KV), criteria A
EMC EMISSION
UL8750, CSA C22.2 No. 250. , ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP67 approved ;13-12
Design refer to EN60335-1
COLD START 60A(twidth=550 s measured at 50% Ipeak) at 230VAC
μ
TOTAL HARMONIC DISTORTION
THD< 20% when output loading60% at 115VAC/230VAC input and output loading75% at 277VAC input
Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
File Name:PWM-90-SPEC 2014-10-21