Datasheet

SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE(OPTION)
AC CURRENT (Typ.)
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.98/115VAC at full load
76% 78% 78%
2.5A/115VAC 1.2A/230VAC
COLD START 40A/230V
<3.5mA / 240VAC
105 ~ 150% rated output power
CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V CH1:5.75 ~ 6.75V CH2:13.8 ~ 16.2V
CH1:5.75 ~ 6.75V CH2:17.25 ~ 20.25V
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, TUV EN60950-1 approved
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
±℃0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
141.5K hrs min. MIL-HDBK-217F (25 )
199*99*50mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
QP-150-3D QP-150D QP-150F
5V 3.3V 24V -12V 12V 24V -12V 15V 24V -15V
10A 10A 10A10A 2.5A 0.6A 4A 2A 0.6A 0.6A
3 ~ 15A 3 ~ 15A 3 ~ 15A0 ~ 15A 0.3 ~ 3A 0 ~ 1A 0 ~ 5A 0.4 ~ 3A 0 ~ 1A 0 ~ 5A 0.4 ~ 3A 0 ~ 1A
150.2W 153.2W 152W
100mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 150mVp-p 150mVp-p 200mVp-p 150mVp-p120mVp-p 120mVp-p
±3.0% ±3.0% ±3.0% ±3.0% ±3.0% ±3.0%±6.0% ±5.0% ±6.0% ±5.0% ±5.0%
±1.0%±1.0%±1.0% ±2.0% ±1.0% ±1.0% ±2.0% ±1.0% ±1.0%±1.0% ±2.0% ±1.0%
±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%±6.0% ±2.0% ±6.0% ±6.0%
±6.0%
Shut down o/p voltage, recovers automatically after temperature goes down
150W Quad Output with PFC Function
QP-150 series
CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 11.4 ~ 13.2V CH1: 4.75 ~ 5.5V CH2: 14.3 ~ 16.5V
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage
Forced air cooling by built-in DC fan
CH4: Polarity is selectable±
Fixed switching frequency at 100KHz
3 years warranty
Features :
800ms, 50ms/230VAC 800ms, 50ms/115VAC at full load
24ms/230VAC 24ms/115VAC at full load
Protection type : Hiccup mode, recovers automatically after fault condition is removed
0.93Kg; 20pcs/19.6Kg/1.28CUFT
CH1 CH1 CH1
OUTPUT NUMBER CH2 CH2 CH2CH3 CH3 CH3CH4 CH4 CH4
..
5V 5V
3A 2A
EMC IMMUNITY
EMC EMISSION
File Name:QP-150-SPEC 2013-12-17