Datasheet

SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE(OPTION)
AC CURRENT (Typ.)
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.95/230VAC PF>0.98/115VAC at full load
73% 75% 74%
2.5A/115VAC 1.2A/230VAC
COLD START 40A/230V
<3.5mA / 240VAC
105 ~ 150% rated output power
CH1:5.75 ~ 6.75V CH2:3.8 ~ 4.4V
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, TUV EN60950-1 approved
-10 ~ +60 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
±℃0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
141.5K hrs min. MIL-HDBK-217F (25 )
199*99*50mm (L*W*H)
0.93Kg; 20pcs/19.6Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
150W Quad Output with PFC Function
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Over load / Over voltage
Forced air cooling by built-in DC fan
CH4: Polarity is selectable±
Fixed switching frequency at 100KHz
3 years warranty
Features :
QP-150 series
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
QP-150-3A QP-150-3B QP-150-3C
5V 5V 5V3.3V
CH2 CH2 CH2
12V
CH3 CH3 CH3
-5V
CH4 CH4 CH4
3.3V 12V -12V 3.3V 15V -15V
10A 10A 10A10A 5A 0.6A 10A 5A 0.6A 10A 0.6A
3 ~ 15A 3 ~ 15A 3 ~ 15A0 ~ 15A 0.4 ~ 5A 0 ~ 1A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A 0 ~ 15A 0.4 ~ 5A 0 ~ 1A
146W 150.2W 152W
100mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 150mVp-p 150mVp-p100mVp-p 100mVp-p
±3.0% ±3.0% ±3.0% ±3.0% ±3.0% ±3.0%±6.0% ±5.0% ±6.0% ±5.0% +8,-6% ±5.0%
±1.0%±1.0%±1.0% ±2.0% ±1.0% ±1.0% ±2.0% ±1.0% ±1.0%±1.0% ±2.0% ±1.0%
±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0%±6.0% ±2.0% ±6.0% ±6.0%
Shut down o/p voltage, recovers automatically after temperature goes down
INPUT
800ms, 50ms/230VAC 800ms, 50ms/115VAC at full load
24ms/230VAC 24ms/115VAC at full load
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1 CH1 CH1
OUTPUT NUMBER
CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V CH1: 4.75 ~ 5.5V CH2: 3.14 ~ 3.63V
..
4A
EMC IMMUNITY
EMC EMISSION
File Name:QP-150-SPEC 2013-12-17

Summary of content (5 pages)