Datasheet

SPECIFICATION-SingleUnit
RCP-1000-12 RCP-1000-24
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
ACCURRENT (Typ.)
12V 24V
60A 40A
0~60A 0~40A
720W 960W
150mVp-p
11.6~12.4V
200mVp-p
23.2~24.8V
1.0% 1.0%
0.5%
0.5%
1000ms,60ms/230VAC atfullload
16ms/230VACatfullload
90~264VAC127~370VDC
47~63Hz
81%
COLDSTART 50A
8.5A/115VAC4.5A/230VAC 10.5A/115VAC5.5A/230VAC 11A/115VAC5.5A/230VAC
<1.1mA /230VAC
RCP-1000-48
48V
21A
0~21A
1008W
300mVp-p
46.3~49.7V
1.0%
0.5% 0.5%
0.5% 0.5%
Universal AC input / Full range
Built-in 5V/0.3A auxiliary power
Built-in active PFC function, PF>0.96
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan with fan speed control
Low profile:1U height
Active current sharing up to 3000W (3 units)in 19" rack, 3 racks max.
can be operated in parallel (up to 8 units)
Remote control for single unit
Built-in remote sense function
Output voltage trimming function
Hot-swap operation
Optional I C serial data bus
AC OK & DC OK signal
Internal ORing diode
3 years warranty
(Note.7)
2
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
87% 89%
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
OVERTEMPERATURE
OVERLOAD
OVERVOLTAGE
105~125% ratedoutputpower
13.2~16.2V
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
75 5 (TSW1)detectonheatsinkofpowertransistor85
5 (TSW2)detectonheatsinkofpowerdiode
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
26.4~32.4V 52.8~64.8V
PROTECTION
SELECTIONGUIDE
SingleUnit:RCP-1000-
Rack:RCP-1U
WholeSystem:RCP-3K1U - -
I
I 12 C
-12 C
C:WithICInterface
C:WithICInterface
:WithoutICInterface
:WithoutICInterface
OutputVoltage
OutputVoltage
I: ACInlet(IEC320-C14)
I: ACInlet(IEC320-C14)
T:TerminalBlock
T:TerminalBlock
-
-
2
2
2
2
1000~3000WFrontEndPowerSystem
Features :
RCP s eries
FileName:RCP series-SPEC2011-12-19