Datasheet

 
SPECIFICATION
                      
                   
          
MODEL
VOLTAGE RANGE
FREQUENCY RANGE
INPU T
INRUSH CURRENT (Typ.)
MONITORING INPUTS
DIGITAL METER
Note.2
CONTROL OUTPUT
RELAY CONTACT
LED INDICATOR
WORKING TEMP.
VOLTAGE TRIM
REMOTE ON/OFF CONTROL
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
VIBRATION
DIMENSION
OTHERS
NOTE
PACKING
AC CURRENT (Typ.)
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
0.35A/115VAC 0.2A/230VAC
30A/115VAC 50A/230VAC
I C signal ( AC OK, DC OK, and over temp erature alarm signals for each RCP-1000 unit ), output voltage of the RCP-1U rack
2
-20 ~ +60
The controlled RCP-1000 unit can be turned ON/OFF on the front panel for RCP-MU
Output voltage of the controlled RCP-1000 unit and be trimmed by 10% on the front panel of RCP-MU±
20~90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
10 ~ 500H z, 2G 10min./1cycle, 60min. each along X, Y, Z axes
440*68*44mm (L*W*H)
1.15Kg; 6pcs/8Kg/1. 27CUFT
RCP-MU
                
                
SAFETY STANDARDS
Design refer to UL60950-1, TUV EN60950-1
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P -FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ENVIRONMENT
SAFETY &
FUNCTION
EMC
File Name:RCP-M U-SPEC 2011-08-19
Power Control and Monitor System
R CP -M U
  
  
       
       
         
  
           
            

  
  
OUTPUT
Dis play the DC output voltage, current, and internal temp erature of each RCP-1000 unit
Remote ON/OFF and output voltage trimming for each RCP-1000 unit
Ala rm for AC Fail, DC Fa il, and Ove r Temperature ; rating : 30VDC, 1A
AC Fail, DC Fail, Over Temperature
EMC IMMUNITY
EMC EMISSION