Datasheet
..
SPECIFICATION
MODEL RD-50A RD-50B
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION Note.4
LOAD REGULATION Note.5
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
5V 12V
CH2
5V
CH1
24V
CH2
6A 2A 4A 1.4A
0.3 ~ 6A 0.3 ~ 3A 0.3 ~ 6A 0.2 ~ 2A
54W 53.6W
80mVp-p 120mVp-p 80mVp-p 150mVp-p
CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V
±2.0% ±7.0% ±2.0% -4,+8%
±0.5% ±1.5% ±0.5% ±1.5%
±0.5% ±3.0% ±0.5% ±3.0%
500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
60ms/230VAC 12ms/115VAC at full load
88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
47 ~ 63Hz
79% 80%
CH1: 5.75 ~ 6.75V
1.3A/115VAC 0.8A/230VAC
COLD START 33A/230VAC
<2mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
UL60950-1, TUV EN60950-1 approved
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
-25 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)on +5V output
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
172.6Khrs min. MIL-HDBK-217F (25℃)
99*97*36mm (L*W*H)
File Name:RD-50-SPEC 2011-08-19
Protection type : Hiccup mode, recovers automatically after fault condition is removed
0.41Kg; 45pcs/19.5Kg/0.9CUFT
50W Dual Output Switching Power Supply
RD-50 series
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
ENVIRONMENT
SAFETY &
EMC
(Note 6)
PROTECTION
℃
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
‧
‧
‧
‧
‧
‧℃
‧
‧℃
‧
‧
‧
■
CH1OUTPUT NUMBER
EMC IMMUNITY
EMC EMISSION