Datasheet
Features :
EMCIMMUNITY
EMCEMISSION
SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE Note.6
RATEDPOWER Note.6
OUTPUT
VOLTAGE ADJ.RANGE
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
500ms,20ms/230VAC1200ms,30ms/115VAC atfullload
36ms/230VAC30ms/115VAC atfullload
47~63Hz
3A/115VAC2A/230VAC
COLDSTART 40A/230VAC
<2mA /240VAC
110~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN61000-6-2(EN50082-2),heavyindustrylevel,criteria A
-20~+70
(Referto"DeratingCurve")
20~90%RH non-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50 )onCH1output
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
218.2Khrsmin.MIL-HDBK-217F(25 )
199*98*38mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
125WDualOutputSwitchingPowerSupply
RID-125 se ri es
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
LINEREGULATION Note.4
LOADREGULATION Note.5
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/25 /70%RH
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note7)
88~132VAC/176~264VACselectedbyswitch248~373VDC(300VACpeak5sec.Nodamage)
RID-125-1224
12V 24V
CH2 CH2 CH2
3.7A 3.7A
1~7A 0.4~5A
133.2W
120mVp-p 200mVp-p
CH1:11.4 ~13.2V
0.5%
2.0%
1.0%
+8,-5%
1.0% 5.0%
85%
CH1:13.8~16.2V
RID-125-1248 RID-125-2448
12V 24V48V 48V
2.3A 2A2.3A 2A
1~7A 0.5~4A0.2~2.5A 0.2~2.5A
138W 144W
120mVp-p 200mVp-p240mVp-p 240mVp-p
CH1:11.4 ~13.2V CH1:22.8 ~26.4V
0.5% 0.5%
2.0% 1.0%
1.0% 1.0%
4.0%
1.0% 1.0%5.0%
+8,-5%
3.0%
85% 86%
CH1:13.8~16.2V CH1:27.6~32.4V
0.7Kg;20pcs/15Kg/0.8CUFT
CH1 CH1 CH1
OUTPUTNUMBER
Isolated output & GND for CH1,CH2
AC input range selectable by switch
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
All using 105 long life electrolytic capacitors
Withstand 5G vibration test
LED indicator for power on
100% full load burn-in test
High realibility
3 years warranty
FileName:RID-125-SPEC2011-08-19