Datasheet

Mechanical Specification
Unit:mm
Block Diagram
CIRCUIT
DETECTION
O.L.P.
EMI
FILTER
RECTIFIERS
&
FILTER
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
FG
CONTROL
O.V.P.
Output Derating VS Input Voltage
INPUT VOLTAGE (VAC) 60Hz
90 10095 120115 160140 200180 240220 264
LOAD (%)
90
100
80
70
60
50
40
Output Derating
AMBIENT TEMPERATURE ( )
LOAD (%)
-20 0 2010 30 40
20
40
80
60
100
6050
70
fosc : 100KHz
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No.
1
2
3
Assignment
AC/N
No Pin
AC/L
Mating Housing
JST VHR JST SVH-21T-P1.1
or equivalent or equivalent
Terminal
DC Output Connector (CN2) : JST B4P-VH or equivalent
Pin No.
1,2
3,4
Assignment
+V
-V
Mating Housing
JST VHR
or equivalent
Terminal
JST SVH-21T-P1.1
or equivalent
File Name:RPS-60-SPEC 2015-08-06
RPS-60 series
1
2
3
4
SVR1
CN2
4- 3.3ψ
101.6
50.8
44.45
3.175
29
95.25 3.175
CN1
2
3
1
(HORIZONTAL)
3 max.
FS1
FS2
AC FUSE
T2.5/250V
AC FUSE
T2.5/250V
HS1
HS2
60W Single Output Medical Type
: Grounding Required
1.HS1,HS2 cannot be shorted.
2.M1 is safety ground. For better EMC performance,
Please secure an electrical connection between
M1,M2 and chassis grounding.
M1
M2