Datasheet

SPECIFICATION
RPS-75-3.3 RPS-75-5 RPS-75-12 RPS-75-15 RPS-75-24 RPS-75-36 RPS-75-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK LOAD (23.5CFM)
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
Note.7
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
AC CURRENT (Typ.)
3.3V
24V 36V 48V
15A 3.2A 2.1A 1.6A
0 ~ 20A 0 ~ 18.7A 0 ~ 8.3A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 2.8A 0 ~ 2.1A
49.5W
66W
70W
93.5W
75.6W
99.6W
75W
100.5W
76.8W
100.8W
75.6W
100.8W
76.8W
100.8W
80mVp-p
2.9 ~ 3.6V
80mVp-p
4.75 ~ 5.5V
120mVp-p
11.4 ~ 13.2V
150mVp-p
13.5 ~ 16.5V
240mVp-p
22.8 ~ 27.6V
300mVp-p
34.2 ~ 39.6V
300mVp-p
45.6 ~ 52.8V
±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±1.5% ±1.5% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
80ms/230VAC 20ms/115VAC at full load
90 ~ 264VAC 127 ~370VDC
47 ~ 63Hz
73% 78% 83% 85% 86% 86%
1.5A/115VAC 1A/230VAC
COLD START 25A/115VAC 50A/230VAC
140 ~ 180% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
3.8 ~ 4.46V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 41.4 ~ 48.6V 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power to recover
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
446.8K hrs min. MIL-HDBK-217F (25 )
127*76.2*31mm (L*W*H)
0.26Kg; 63pcs/16.3Kg/1.35CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Heat Sink HS1,HS2,HS3 can not be shorted.
7. .Touch current was measured from primary input to DC output
File Name:RPS-75-SPEC 2015-08-06
OVER VOLTAGE
SAFETY STANDARDS
RPS-75 series
Features :
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
Universal AC input / Full range
Low leakage current <100 A
Protections: Short circuit / Overload / Over voltage
Free air convection for rated power and 23.5CFM forced air
convection for peak load
Medical safety approved (2 x MOPP between primary to secondary)
No load power consumption<0.75W
Fixed switching frequency at 65KHz
3 years warranty
Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
75W Single Output Medical Type
5V 12V 15V
14A 6.3A 5A
82%
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A
EMC IMMUNITY
EMC EMISSION
Earth leakage current < 150 A/264VAC , Touch current < 100 A/264VACμ
μ
μ
ISOLATION LEVEL
Primary-Secondary:2xMOPP, Primary-Earth:1xMOPP
EN 60601-1
IEC 60601-1
8