Datasheet

ENVIRONMENT
PROTECTION
SPECIFICATION
MODEL RS-150-3.3 RS-150-5 RS-150-12 RS-150-15 RS-150-24 RS-150-48
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
RIPPLE&NOISE(max.) Note.2
OUTPUT VOLTAGE ADJ.RANGE
VOLTAGETOLERANCE Note.3
LINEREGULATION Note.4
LOADREGULATION Note.5
SETUP,RISETIME
HOLDTIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
3.3V 5V 12V 15V 24V 48V
30A 26A 12.5A 10A 6.5A 3.3A
0~30A 0~26A 0~12.5A 0~10A 0~6.5A 0~3.3A
99W 130W 150W 150W 156W 158.4W
80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p
3.2V~3.5V 4.75~5.5V 11.4~13.2V 14.25~16.5V 22.8~26.4V 45.6~52.8V
3.0% 2.0% 1.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
2.0% 1.0% 0.5% 0.5% 0.5% 0.5%
800ms,20ms/230VAC1200ms,30ms/115VAC atfullload
28ms/230VAC20ms/115VAC atfullload
88~132VAC/176~264VACselectedbyswitch248~373VDC(Withstand300VACsurgefor5sec.Withoutdamage)
47~63Hz
74%
3.8~4.45V 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V 55.2~64.8V
78% 83% 84% 86% 87%
3A/115VAC2A/230VAC
COLDSTART 40A/230VAC
<2mA /240VAC
110~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2)heavyindustrylevel,criteria A
-25~+70 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
244KHrsmin.MIL-HDBK-217F(25 )
199*98*38mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
FileName:RS-150-SPEC2005-09-13
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
0.7Kg;20pcs/15Kg/0.8CUFT
150WSingleOutputSwitchingPowerSupply
RS-150 se ri es
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
EMICONDUCTION&RADIATION
SAFETY &
EMC
(Note6)
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
long life electrolytic capacitors
Features :

Summary of content (2 pages)