Datasheet
SPECIFICATION
MODEL RS-25-3.3 RS-25-5 RS-25-12 RS-25-15 RS-25-24 RS-25-48
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION Note.4
LOADREGULATION Note.5
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
3.3V 5V 12V 15V 24V 48V
6A 5A 2.1A 1.7A 1.1A 0.57A
0~6A 0~5A 0~2.1A 0~1.7A 0~1.1A 0~0.57A
19.8W 25W 25.2W 25.5W 26.4W 27.36W
80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p
2.85~3.6V 4.75~5.5V 10.8~13.2V 13.5~16.5V 22~27.6V 42~54V
3.0% 2.0% 1.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
2.0% 1.0% 0.5% 0.5% 0.5% 0.5%
1800ms,23ms/230VAC4000ms,30ms/115VAC atfullload
80ms/230VAC14ms/115VAC atfullload
88~264VAC125~373VDC (Withstand300VACsurgefor5sec.Withoutdamage)
47~63Hz
73.5%
3.8~4.45V 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V 55.2~64.8V
78.5% 81.5% 83.5% 86% 85%
0.7A/115VAC0.4A/230VAC
COLDSTART 30A/230VAC
<2mA /240VAC
110~180% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
-20~+70
(Referto"DeratingCurve")
20~90%RH non-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
309.7Khrsmin.MIL-HDBK-217F(25 )
78*51*28mm(L*W*H)
FileName:RS-25-SPEC2011-08-19
Protectiontype: Shutoffo/pvoltage,clampingbyzenerdiode
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC/25 /70%RH
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
ENVIRONMENT
SAFETY &
EMC
(Note6)
PROTECTION
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
25WSingleOutputSwitchingPowerSupply
RS-25 se ri es
CompliancetoEN61000-4-2,3,4,5,6,8,11,lightindustrylevel,criteria A
0.2Kg;60pcs/13Kg/0.46CUFT
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
long life electrolytic capacitors
No load power consumption<0.5W
Features :
EMCIMMUNITY
EMCEMISSION