Datasheet

SPECIFICATION
MODEL RS-50-3.3 RS- -550 RS- -1250 RS- -1550 RS- -2450 RS- -4850
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION Note.4
LOADREGULATION Note.5
SETUP,RISETIME
HOLDTIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
3.3V 5V 12V 15V 24V 48V
10A 10A 4.2A 3.4A 2.2A 1.1A
0~10A 0~10A 0~4.2A 0~3.4A 0~2.2A 0~1.1A
33W 50W 50.4W 51W 52.8W 52.8W
80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p
3V~3.6V 4.75~5.5V 10.8~13.2V 13.5~16.5V 22~27.2V 42~54V
3.0% 2.0% 1.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
2.0% 1.0% 0.5% 0.5% 0.5% 0.5%
500ms,20ms/230VAC1200ms,30ms/115VAC atfullload
60ms/230VAC14ms/115VAC atfullload
88~264VAC125~373VDC(Withstand300VACsurgefor5sec.Withoutdamage)
47~63Hz
72%
3.8~4.45V 5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V
78% 81% 83% 84% 86%
1.3A/115VAC0.8A/230VAC
COLDSTART 33A/230VAC
<2mA /240VAC
110~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
-25~+70 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
228Khrsmin.MIL-HDBK-217F(25 )
99*97*36mm(L*W*H)
FileName:RS-50-SPEC2006-04-12
0.41Kg;45pcs/19.5Kg/0.9CUFT
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
50WSingleOutputSwitchingPowerSupply
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
long life electrolytic capacitors
Features :
RS-50 se ri es
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
ENVIRONMENT
SAFETY &
EMC
(Note6)
PROTECTION
EMICONDUCTION&RADIATION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2)heavyindustrylevel,criteria A
55.2~64.8V

Summary of content (2 pages)