RSD-30 series
Hold-up Time
TIME TIME
TIMETIME
LOAD
LOAD
LOAD
LOAD
Output Voltage Adjustment
This function is optional, which the standard product does not have it. If you do need the function, please contact MW for details.
RSD-30G-3.3 RSD-30G-5
RSD-30G-12 RSD-30G-24
30W Reliable Railway DC-DC Converter
File Name:RSD-30-SPEC 2020-06-05
EN50155: 2007 version - H type is in compliance with S2 level (10ms), while G and L types are in compliance with S1 level (3ms) at full load
output condition. To fulfil the requirements of S2 level (10ms), G types require de-rating their output load to 80%,
please refer to the curve diagrams below.
EN50155: 2017 version - Comply with S1 level (3ms)