Data Sheet
Function Manual
EXTERNAL VOLTAGE (DC)
PIN3 PV
PIN4 GND
1. Remote Sense
Sense lines should be twisted in pairs to minimize noise pick-up.
※ The Remote Sense compensates voltage drop on the load wiring up to 0.5V
◎ The signal should be connected to the positive terminal of the load whereas signal to the negative terminal.+S -S
LOAD
-V
+V
PIN2 -S
PIN1 +S
3. Remote ON-OFF Control
The power supply can be turned ON/OFF individually or along with other units by using the "Remote ON-OFF" function.
PIN7 Remote ON-OFF
PIN11 +5V-AUX
Between andRemote ON-OFF +5V-AUX
Switch Short
Switch Open
Power Supply Status
ON
OFF
switch
File Name:RSP-2000-SPEC 2020-03-27
2000W Power Supply with Single Output
RSP-2000 series
◎+S +V -S -V& , & also need to be connected on CN501.
30
40
60
OUTPUT VOLTAGE(%)
EXTERNAL VOLTAGE (DC)
80
100
115
Vout
0.40
for 12V model
for 24V,48V
model
1 2 3 4 4.7 5
V
40 60 80 100 115
V
100
40
60
87
20
OUTPUT CURRENT (%)
OUTPUT VOLTAGE (%)
20
Non-Linear
※ In addition to the adjustment via the built-in potentiometer, the output voltage can be trimmed to 40~115% of the nominal voltage by applying
EXTERNAL VOLTAGE.
2. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim)
◎ The rated current should change with the
Output Voltage Programming accordingly.
PIN2 -S
PIN1 +S
+V
CN501
CN501
CN501
+V
+V
-V
-V
-V