The power supply can be turned ON/OFF by using the “Remote ON-OFF” function.
Fig 2.1
REMOTE
ON-OFF
REMOTE
ON-OFF
The remote sensing compensates voltage drop on the load wiring up to 0.5V.
1.Remote Sense
+S
5317
+VS
6428
-S PV
-VS PS
DC_OK
12V-AUX
PC
CN50
PO GND
GND
13
G-AUX
14
Fig 1.1
PIN3 -S
PIN1 +S
750W Single Output Power Supply
RSP-750 series
Function Manual
2.Remote ON-OFF
File Name:RSP-750-SPEC 2020-03-27
LOAD
LOAD
-
-
+
+
1
1
13
13
2
2
14
14
By factory default, on CN50 (pin13) and (pin14), (pin5) and (pin6), and (pin7) and (pin8, respectively, are, Remote ON-OFF 12V-AUX PV PS PC PO
When multiple power supplies need to turn ON/OFF simultaneously by Remote ON-OFF control, -S & -V on CN50, as well as +S & +V, on each power
supply should be connected.
The signal should be connected to the positive terminal of the load whereas signal to the negative terminal.+S -S
shorted when shipped. The power supply will have no output if the shorting connector is not assembled unless certain functin needs to be activated.
Between Remote andON-OFF(pin13) 12V-AUX(pin14)
SW close (Short)
SW open (Open)
ON
Power Supply Status
OFF
SW
+S
1357
+VS
2468
-S PV
-VS PS
DC_OK
12V-AUX
PC
CN50
PO GND
GND
13
G-AUX
14