User Manual
InstallationManual
Type:DC‐DCconverter(Families:PSD,SD,RSD)
Introduction
ADC‐DCconverterisadeviceusedto convertaDCsourcefromonevoltageleveltoanother.MeanWell’s DC‐DC
convertersequippedwithinternalEMIfilterstagethatpossesstherequiredEMCperformance.
Installation
(1)Beforecommencing any installation or maintenance work, please disconnect your system fromthe
utility.Ensurethatitcannotbere‐connectedinadvertently!
(2)
ForPCBtype,atleast5mminsulationdistancearoundtheunitshouldbekept.
(3)
Allowgoodventilationfortheunitinusetopreventitfromoverheating.Also,a10‐15cmclearance
mustbekeptwhentheadjacentdeviceisaheatsource.
(4)Mountingorientationsotherthanstandardorientationoroperateunderhigh ambienttemperature
may increase the internal component temperature and will require a de‐rating in output current.
Pleaserefer to the specification sheetsto receivethe optimum mounting position andinformation
aboutthede‐ratingcurve.
(5)
Recommendedinput/outputwiresareshownasbelow.
AWG 18 16 14 12 10 8
RatedCurrentof
Equipment(Amp)
6A 6‐10A 10‐16A 16‐25A 25‐32A 32‐40A
Cross‐sectionof
Lead(mm
2
)
0.75 1.00 1.5 2.5 4 6
Note:Currenteachwirecarriesshouldbede‐ratedto80%ofthecurrent
suggestedabovewhenusing5ormorewiresconnectedtotheunit.
(6)ForPCBtype,compatiblematinghousingpleasereferstothespecifications
(7)For enclosed type, make sure that all strands of each stranded wire enter the terminal connection and the
screwterminalsaresecurelyfixedtopreventpoorcontact.
(8)Forotherinformationabouttheproducts,pleaserefertowww.meanwell.com
fordetails.
Warning/Caution!!
(1)Riskofelectricalshockandenergyhazard.Allfailureshouldbeexaminedbyaqualifiedtechnician.
Pleasedonottrytofixtheconverterbyyourself!
(2)
Riskofirreparabledamage.Donotreversepolarity,bothinputandoutput.
(3)
Pleasedonotinstallconvertersinplaceswithhighmoistureornearthewater.
(4)
Pleasedonotinstallconvertersinplaceswithhighambienttemperatureornearfiresource.Please
refertothespecificationsaboutthemaximumambienttemperaturelimitations.
(5)
Outputcurrentandoutputwattagemustnotexceedtheratedvaluesonspecifications.
(6)
Theground(FG)mustbeconnectedtoearthground.
(7)
For system considerations, PCB and enclosed type converters may require an additional inrush
currentlimitingcircuittosuppresshighinrushcurrentsurges.Ifyouareuncertainaboutthatcircuit,
contactMeanWell.
(8)AllofMeanWell’sconvertersaredesignedinaccordancewithEMCregulationsandtherelatedtestreports
are available by request. Since they are belong to component power supplies and will be installed inside
systemenclosure,whentheyareintegratedintoasystem,theEMCcharacteristicsoftheend
systemmustbe
re‐verifiedagain.