Datasheet
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
VOLTAGE RANGE
Note.5
EFFICIENCY (Typ.)
INPUT
FUNCTION
INRUSH CURRENT (Typ.)
OVER TEMPERATURE
WORKING TEMP.
OUTPUT OK SIGNAL
REMOTE ON/OFF CONTROL
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
DC CURRENT (Typ.)
CURRENT (AT NO LOAD)
500ms, 50ms at full load
19 ~ 72VDC
24.2A/19VDC 24.8A/24VDC 12A/48VDC
Max. 0.2A/48VDC
60A/48VDC
105 ~ 125% rated output power
Protection type : Constant current limiting, shut down o/p voltage after about 5 sec., re-power on to recover
16 ~ 19V 30.8 ~ 35.2V 62 ~ 68V 16 ~ 19V 30.8 ~ 35.2V 62 ~ 68V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +60 (Refer to "Derating Curve")℃
Please refer to function manual
Open collector signal low when PSU turns on, max. sink current :10mA
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.02%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
196.3K hrs min. MIL-HDBK-217F (25 )℃
215*115*50mm (L*W*H)
1.15Kg; 12pcs/14.8Kg/0.92CUFT
86% 88% 89% 87%
8A/72VDC 6A/96VDC
60A/96VDC
Max. 0.1A/96VDC
89% 90%
±0.5% ±0.5% ±0.5% ±0.5%
72 ~ 144VDC
±0.5% ±0.5%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
150mVp-p
11 ~ 15V
150mVp-p
23 ~ 30V
150mVp-p
46 ~ 60V
150mVp-p
11 ~ 15V
150mVp-p 150mVp-p
23 ~ 30V 46 ~ 60V
12V
40A
0 ~ 40A
480W
24V
21A
0 ~ 21A
504W
48V
10.5A
0 ~ 10.5A
504W
12V
40A
0 ~ 40A
480W
24V 48V
21A 10.5A
0 ~ 21A 0 ~ 10.5A
504W 504W
SD-500L-12 SD-500L-24 SD-500L-48 SD-500H-12 SD-500H-24 SD-500H-48
1. All parameters NOT specially mentioned are measured at 48, 96VDC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
SAFETY STANDARDS
IEC60950-1 CB approved by TUV
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
•DC input active surge current limiting
•Wide 4:1~2:1 DC input range (24V: 19~72VDC, 96V:72~144VDC)
•Protections: Short circuit / Overload / Over voltage / Over temperature
/ Input polarity(by fuse)
•2000VAC I/O Isolation
•Forced air cooling by built-in DC fan with fan speed control function
•Output OK Signal
•Built-in remote ON-OFF control
•Built-in remote sense function
•3 years warranty
■
Features :
500W Single Output DC-DC Converter
SD-500 series
File Name:SD-500-SPEC 2013-12-17
EMC IMMUNITY
EMC EMISSION