Datasheet

SPECIFICATION
SP-100-3.3 SP-100-5 SP-100-7.5 SP-100-12 SP-100-13.5 SP-100-15 SP-100-24 SP-100-27 SP-100-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
SAFETY STANDARDS
HARMONIC CURRENT
EMS IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
REMOTE CONTROL(OPTION)
FUNCTION
AC CURRENT
3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
20A 20A 13.5A 8.5A 7.5A 6.7A 4.2A 3.8A 2.1A
0 ~ 20A 0 ~ 20A 0 ~ 13.5A 0 ~ 8.5A 0 ~ 7.5A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 3.8A 0 ~ 2.1A
66W 100W 101.25W 102W 101.25W 100.5W 100.8W 102.6W 100.8W
100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p
2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5% 0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%1.0% 1.0% 1.0%
600ms, 30ms, 20ms at full load
85 ~ 264VAC 120 ~ 370VDC
47~63Hz
PF>0.93/230VAC PF>0.98/115VAC at full load
70% 76% 78% 80% 80% 82% 84% 83% 82%
1.7A/115VAC 0.8A/230VAC
COLD START 40A/230VAC
<2mA / 240VAC
105 ~ 150% rated output power
3.63 ~ 4.46V 5.5 ~ 6.75V
8.25 ~ 10.13V
13.2 ~ 16.2V
14.85 ~ 18.23V
16.5 ~ 20.25V 26.4 ~ 32.4V
29.7 ~ 36.45V
52.8 ~ 64.8V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF
UL1950, TUV EN60950 Approved
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
211.3K hrs min. MIL-HDBK-217F (25 )
179*99*45mm (L*W*H)
0.6Kg; 20pcs/12Kg/1.17CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SP-100-SPEC 2004-02-02
100W Single Output with PFC Function
SP-100 series
Universal AC input / full range
Built-in active PFC function, PF>0.93
Protections:Short circuit/Over load/Over voltage
Built-in constant current limiting circuit
Remote ON-OFF control(Optional)
LED indicator for power on
100% full load burn-in test
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
Features :
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
EMI CONDUCTION & RADIATION
3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V14.3 ~ 16.5V