Data Sheet

240W Single Output with PFC Function
SP-240 series
Model: SP-240-24 Test Report 1 / 6
MODELSP-240-24
OUTPUT FUNCTION TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 RIPPLE & NOISE
V1150
mVp-p (Max )
I/P 230VAC
O/PFULL LOAD
Ta25
V1
35 mVp-p (Max )
P
2 OUTPUT VOLTAGE
ADJUST RANGE
CH120 V ~ 28 V I/P 230 VAC
I/P 115 VAC
O/PMIN LOAD
Ta25
19.33
19.33
V ~
V ~
29.36
29.36
V/ 230 VAC
V/ 115 VAC
P
3 OUTPUT VOLTAGE
TOLERANCE
V11 %~ -1 % (Max) I/P100 VAC / 264 VAC
O/PFULL/ MIN LOAD
Ta25
V1
0.05 %~ -0.05 %
P
4 LINE REGULATION
V1 0.2 %~ -0.2 % (Max) I/P100 VAC ~ 264 VAC
O/PFULL LOAD
Ta25
V1
0 %~ 0 %
P
5 LOAD REGULATION
V1 0.5 %~ -0.5 % (Max)
I/P 230 VAC
O/PFULL ~MIN LOAD
Ta25
V1
0.05 %~ -0.05 %
P
6 SET UP TIME
230VAC
800 ms (Max)
I/P 230 VAC
I/P 115 VAC
O/PFULL LOAD
Ta25
230VAC/ 400 ms
P
115VAC
1500 ms (Max) 115VAC/ 800 ms
7 RISE TIME
230VAC
50 ms (Max)
I/P 230 VAC
I/P 115 VAC
O/PFULL LOAD
Ta25
230VAC/ 25 ms
P
115VAC
50 ms (Max) 115VAC/ 24 ms
8 HOLD UP TIME
230VAC
20 ms (TYP)
I/P 230 VAC
I/P 115 VAC
O/PFULL LOAD
Ta25
230VAC/ 22 ms
P
115VAC
20 ms (TYP)
115VAC/ 22 ms
9 OVER/UNDERSHOOT
TEST
< +5%
I/P 230 VAC
O/PFULL LOAD
Ta25
TEST
< +5 %
P
10 DYNAMIC LOAD
V1
2400 mVp-p
I/P 230 VAC
O/PFULL /Min LOAD 90%DUTY/
1KHZ
Ta25
404 mVp-p
P