Data Sheet

240W Single Output with PFC Function
SP-240 series
Model: SP-240-24 Test Report 4 / 6
ENVIRONMENT TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 TEMPERATURE RISE TEST
MODELSP-240-5
1. ROOM AMBIENT BURN-IN0.5 HRS
I/P 230VAC O/P FULL LOAD Ta= 26.6
2. HIGH AMBIENT BURN-IN 2 HRS
I/P 230VAC O/P FULL LOAD Ta= 49.5
NO Position P/N
ROOM AMBIENT
Ta= 26.6
HIGH AMBIENT
Ta= 49.5
1
LF1 LF108-R2
38.9 56.7
2
BD1 6A/800V GLASS KBJ608G
45.2 65.0
3
TSW1
ST-22W-R2 90
45.7 64.2
4
Q1 IRFB20N50K 20A/500V
47.2 65.9
5
D2 STTH8S06D
47.7 65.1
6
C5
100u/400V 105 18*25 KMG
41.1 58.8
7
L1 TR412
47.6 66.6
8
Q2 2SK4115 7A/900V
53.2 77.5
9
U1 FAN4800IN
48.7 66.1
10
T1 TF1926
80.4 97.0
11
D3 BYV26EGP 1A/1KV
64.3 83.6
12
RG1 L7812CV 1.0A/12V
50.4 69.6
13
C201 47u/35V L6Kh 5*11 ZLH
52.5 77.9
14
L100 TR901 Ku106125-2
52.5 76.7
15
D101 STPS30L30CT
59.3 75.7
16
C103 3900u/10V UL10Kh 12.5*25 ZLH
51.4 69.3
17
R10 3W 100 5% MINI
79.7 99.6
P
2 OVER LOAD BURN-IN TEST NO DAMAGE
1 HOUR ( MIN )
I/P 230 VAC
O/P110 LOAD
Ta25
TESTOK
P
3 LOW TEMPERATURE
TURN ON TEST
TURN ON AFTER 2 HOUR
I/P 230 VAC
O/P100 LOAD
Ta= -30
TESTOK
P
4 HIGH HUMIDITY
HIGH TEMPERATURE
HIGH VOLTAGE
TURN ON TEST
AFTER 12 HOURS
IN CHAMBER ON
CONTROL 50
NO DAMAGE
I/P 272 VAC
O/PFULL LOAD
Ta= 50
HUMIDITY= 95 %R.H
TESTOK
P
5 TEMPERATURE
COEFFICIENT
+ 0.03 %(0~50) I/P 230 VAC
O/PFULL LOAD
+ 0.01 %(0~50)
P
6 VIBRATION TEST 1 Carton & 1 Set
(1) Waveform Sine Wave
(2) Frequency10~500Hz
(3) Sweep Time10min/sweep cycle
(4) Acceleration2G
(5) Test Time1 hour in each axis (X.Y.Z)
(6) Ta25
TESTOK
P