Data Sheet
240W Single Output with PFC Function
SP-240 series
Model: SP-240-24 Test Report 5 / 6
SAFETY TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 WITHSTAND VOLTAGE
I/P-O/P: 3 KVAC/min
I/P-FG: 1.5 KVAC/min
O/P-FG: 0.5 KVAC/min
I/P-O/P: 3.6 KVAC/min
I/P-FG: 1.8 KVAC/min
O/P-FG: 0.6 KVAC/min
Ta:25℃
I/P-O/P:
7.3 mA
P
I/P-FG:
6.84
mA
O/P-FG:
5.54 mA
NO DAMAGE
2 ISOLATION RESISTANCE
I/P-O/P:500VDC>100MΩ
I/P-FG: 500VDC>100MΩ
O/P-FG:500VDC>100MΩ
I/P-O/P: 500 VDC
I/P-FG: 500 VDC
O/P-FG: 500 VDC
Ta:25℃/70%RH
I/P-O/P:
12
GΩ
P
I/P-FG:
3 GΩ
O/P-FG:
3.5
GΩ
NO DAMAGE
3 GROUNDING CONTINUITY FG(PE) TO CHASSIS
OR TRACE < 100 mΩ
40 A / 2min
Ta:25℃ / 70%RH
8 mΩ
P
4 APPROVAL
TUV: Certificate NO :R50159049
UL: File NO :E183223
P
E.M.C TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 HARMONIC EN61000-3-2
CLASS A
CLASS D
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
PASS
P
2 CONDUCTION EN55022
CLASS B
I/P: 230 VAC (50HZ)
O/P:FULL/50% LOAD
Ta:25℃
PASS
Test by certified Lab
P
3 RADIATION EN55022
CLASS B
I/P: 230 VAC (50HZ)
O/P:FULL LOAD
Ta:25℃
PASS
Test by certified Lab
P
4 E.S.D EN61000-4-2
LIGHT INDUSTRY
AIR:8KV / Contact:4KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
P
5 E.F.T EN61000-4-4
LIGHT INDUSTRY
INPUT: 1KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
P
6 SURGE IEC61000-4-5
LIGHT INDUSTRY
L-N :1KV
L,N-PE:2KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
P
7
Test by certified Lab & Test Report Prepare
M.T.B.F & LIFE CYCLE CALCULATION
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 CAPACITOR
LIFE CYCLE
SP-240-5:SUPPOSE C103 IS THE MOST CRITICAL COMPONENT
I/P: 230VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME=498365.4
I/P: 230VAC O/P:FULL LOAD Ta=40 ℃ LIFE TIME=249128.4
HRS
HRS
P
2 MTBF MIL-HDBK-217F NOTICES2 PARTS COUNT
TOTAL FAILURE RATE: 284K HRS
P