Data Sheet
240W Single Output with PFC Function
SP-240 series
Model: SP-240-24 Test Report 6 / 6
COMPONENT STRESS TEST
NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT
1 Power Transistor
( D to S) or (C to E) Peak Voltage
Q2 Rated:
2SK4115 7A/900V
I/P:High-Line +3V = 267 V
O/P: (1)Full Load Turn on
(2) Output Short
Ta:25℃
(1) 828 V
P
(2) 812 V
2 Diode Peak Voltage
D 100 Rated:
STPS20120CT 20A/120V
I/P:High-Line +3V = 267 V
O/P: (1)Full Load Turn on
(2)Output Short
Ta:25℃
(1) 88.4 V
P
(2) 91 V
3 PFC Transistor
( D to S) or (C to E) Peak Voltage
Q1 Rated:
IRFB20N50K 20A/500V
I/P:High-Line +3V = 267 V
O/P: (1)Full Load Turn on
(2)Output Short
Ta:25℃
(1)
(2)
444
436
V
V
P
4 Input Capacitor Voltage
C 5 Rated:
100u/400V 105℃ 18*25 KMG
I/P:High-Line +3V = 267 V
O/P: (1)Full Load Turn on /Off
(2) Min load Turn on /Off
(3)Full Load /Min load Change
Ta:25℃
(1) 376 V
P
(2) 377 V
(3) 391 V
5 Control IC Voltage Test
U 1 Rated:
PWM FAN4800IN 18V
I/P:High-Line +3V = 267 V
O/P: (1)Full Load Turn on /Off
(2) Min load Turn on /Off
(3)Full Load /Min load Change
Ta:25℃
(1) 15.25 V
P
(2) 15 V
(3) 15.6 V
DATE SAMPLE TEST RESULT TESTER APPROVAL
2009/6/5 RD SAMPLE PASS SANFORD SU VINCENT TSENG
2009/7/28
PRODUCT SAMPLE
W0907A36
PASS SANFORD SU VINCENT TSENG
2003/12/12 A50-F023