Datasheet
SPECIFICATION
SP-750-5MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
WORKING TEMP.
REMOTE CONTROL
Note.5
POWER GOOD/FAIL
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
5V
120A
0 ~ 120A
600W
120mVp-p
4.75 ~ 5.5V
±2.0%
±0.5%
±2.0%
1500ms, 50ms/230VAC 1500ms, 50ms/115VAC at full load
16ms/230VAC 16ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
80%
8.8A/115VAC 4.2A/230VAC
27A/115VAC 45A/230VAC
<2.0mA / 240VAC
105 ~ 125% rated output power
5.75 ~ 6.75V
13.8 ~ 16.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V 57.6 ~ 67.2V
Protection type : Constant current limiting, unit will Hiccup after 3 sec.
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +60 (Refer to "Derating Curve")℃
RC+/RC- short power on, open power off
50ms/1ms
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
± ℃ ℃0.05%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
105.4K hrs min. MIL-HDBK-217F (25 )℃
278*127*63.5mm (L*W*H)
2.9Kg; 6pcs / 18.4Kg / 0.98CUFT
85% 87% 89% 89% 90%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
120mVp-p
10 ~ 13.5V
120mVp-p
13.5 ~ 16.5V
120mVp-p
22 ~ 26.4V
120mVp-p
24 ~ 30V
120mVp-p
43 ~ 56V
12V
62.5A
0 ~ 62.5A
750W
15V
50A
0 ~ 50A
750W
24V
31.3A
0 ~ 31.3A
751.2W
27V
27.8A
0 ~ 27.8A
750.6W
48V
15.7A
0 ~ 15.7A
753.6W
SP-750-12 SP-750-15 SP-750-24 SP-750-27 SP-750-48
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
5. The power supply unit will have no output if the shorting connector is not assembled between RC+ & RC-.
File Name:SP-75 0-SPEC 2013 -11-07
POWER FACTOR (Typ.) PF>0.96/230VAC PF>0.99/115VAC at full load
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
750W Single Output Power Supply
‧
Universal AC input / Full range
‧
AC input active surge current limiting
‧
Built-in active PFC function,PF>0.96
‧
Protections: Short circuit / Overload / Over voltage / Over temperature
‧
Forced air cooling by built-in DC ball bearing fan
‧
High power density 5.48/inch
3
‧
Built-in constant current limiting circuit
‧
With power good and fail signal output
‧
Built-in remote ON-OFF control
‧
Built-in remote sense function
‧
3 years warranty
■
Features :
SP -7 5 0
s eri es
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
FUNCTION
EMC IMMUNITY
EMC EMISSION