User manual

Clogwithforeignbodies Removetheforeign objects
Fandoes
notspin
Malfunctionofthefan
Repairrequired.Pleasesenditback
tousoranyofourdistributors
Shortcircuitprotection
Makesuretheoutputisnot
overloadedorshortcircuited
Batteriesareagedorbroken Replacethebatteries
Discharging
periodof
batteriesis
tooshort
Batterycapacityistoosmall
Reconfirmthespecificationand
enlargethebatterycapacityas
suggested
Status PossibleReasons WaystoEliminate
Abnormalinput
Checkthe ACorDCinputsources.
Makesurethevoltageiswithinthe
requiredrange.
Overtemperature
protection
Makesurethattheventilationisnot
blockedorwhethertheambient
temperatureistoohigh.Please
deratingtheoutputusageorreduce
theambienttemperature.
Overloadprotection
Makesuretheoutputloaddoesnot
exceedtheratedvalueorthe
instantaneousstartupcurrentisnot
toohigh.(forinductiveorcapacitive
loads)
No ACoutput
voltage
10
(1)Since inductive loads or motor based equipments need a large start up
(2)Whentheoutputarecapacitiveorrectifiedequipments(suchasswitching
current (6~10 times of its rated current), the inverter may not start up
successfullywiththesekindsofload.
powersupply),itissuggestedtooperatetheseequipmentatnoloadorlight
load. Toensureproperoperation,youshouldincreasetheloadsonlyafter
TS-700/1000hasstartedup.
7.FailureCorrectionNotes
TS-700/1000 should be serviced by a professional technician. Any improper
usageormodificationmaydamagetheunitorresultinshockhazard.Ifyouare
not able to clear the failure condition, please contact Mean WELL or any of our
distributorsforrepairservice.
8.Warranty
Three years of global warranty is provided for TS-700/1000 under normal
operatingconditions.Pleasedonotchangecomponentsormodifytheunit
byyourselforMEANWELL mayreservetherightnottoprovidethe
completewarranty.