User manual

14
(B)SuggestedBatteryTypeandCapacity
5A ~25A
Battery Type
Battery
Capacity
Lead-acid
12V/120Ah~ 24V/60Ah~ 48V/30Ah~
12V/400Ah 24V/200Ah 48V/100Ah
112 212 124 224 148 248
TN/TS-1500
10A ~13A 1.25
1.5
2.5
4
6
10
16
25
35
50
16
Choosingsuitable
wiresbasedonthe
ratingofsolarpanels
anddistancefrom
theinverter
14
12
10
8
6
Modelsusing48V
batteries
Modelsusing24V
batteries
Modelsusing12V
batteries
4
2
1
0
13A ~16A
16A ~25A
25A ~32A
32A ~40A
40A ~63A
63A ~80A
80A ~100A
100A ~125A
125A
AWG Note
Cross-sectionof
Lead (mm )
2
RatedCurrentof
Equipment(Amp)
Table7.1:SuggestionforWireSelection
InputCurrent
fromSolarPanel
(A)Wiring for Batteries: Wire connections should be as short as possible and
less than 1.5 meter is highly recommended. Make sure that suitable wires are
chosen based on Safety requirement and rating of current. Too small cross-
section will result in lower efficiency, less output power, and the wires may
also become overheated and cause danger. Please refer to Table 7.1 and
consultourlocaldistributorifyouhaveanyquestions.
7.Installation&Wiring
(C)RequirementofInstallation:
The unit should be mounted on a flat surface or holding rack with suitable
strength. In order to ensure the lifespan of the unit, you should refrain from
operating the unit in environment of high dust or moisture. This is a power
supply with built-in DC fan. Please make sure the ventilation is not blocked.
We recommend that there should be no barriers within 15cm of the ventilating
holes.