User manual
3
2.3 SystemBlockDiagram
Figure2.1SystemBlockDiagram
TN-1500Inverter
AC
Input
AC
Output
ACcharger
Solarcharger
Battery
Fuse
Fuse
12V/24V/48V
DC/DC
Converter
SolarPanel
EMI
filter
200VD C
CPU
Controller
Polarity
detect
DC/AC
Inverter
LOAD
120V/230V
Circuit
Breaker
50Hz/60Hz
/400VD C
LED
Display
A
B
C
D
E
F
G
3.1 FrontPanel
POWER on/off switch: The inverter will turn OFF if the switch is in the OFF
ACoutputoutlet: Tosatisfyapplicationdemandofdifferentgeographicareas
No Fuse Breaker; Reset: Under "Bypass Mode", when the AC output is
Ventilation holes: The inverter requires suitable ventilation to work properly.
Function Setting: Operating Mode, Output voltage, frequency, and saving
LEDIndicatingPanel: Operatingstatus,loadcondition,andalltypesof
Communication Port: For remote monitoring purpose, the unit can be
position.
allovertheworld,therearemanyoptional ACoutletstochoosefrom.
shorted or the load current exceeds the rated current of the No Fuse Breaker,
Please make sure there is good ventilation and the lifespan of the inverter can
modecanbesetthroughthisbutton.
warningswillbedisplayedonthispanel.
connected to a PC through this communication port by using the optional cable
andmonitoringsoftware.
preserved.
the No Fuse Breaker will open and that stops bypassing energy from the utility
getting to prevent possible danger. When the abnormal operating condition is
removed,usercanpressdownontheResetbuttontoresumeoperation.
3.Userinterface