Data Sheet

SPECIFICATION
10A
0.63A
21 ~ 30VDC
87.5%
5A
0.32A
42 ~ 60VDC
88%
10A
0.63A
21 ~ 30VDC
87.5%
5A
0.32A
42 ~ 60VDC
88%
MAXIMUM OUTPUT POWER
WAVEFORM
Note.1
OUTPUT
FREQUENCY
Note.5
AC REGULATION Note.1
VOLTAGE RANGE (Typ.) Note.3
EFFICIENCY (Typ.) Note.1
DC CURRENT (Typ.)
INPUT
INPUT
BATTERY
OUTPUT
ENVIRONMENT
FUSE
SAFETY &
EMC
BAT. LOW ALARM
BAT. LOW SHUTDOWN
OVER TEMPERATURE
OUTPUT SHORT
BAT. POLARITY
GFCI PROCTECTION
PROTECTION
PROTECTION
True sine wave (THD<3%)
20A
1.25A
10.5 ~ 15VDC
86%
30A*2 30A*1 15A*1
15A*130A*1
±3.0% at rated input voltage
10.5 ~ 15VDC
86%
20A
1.25A
30A*2
85 5℃±
Protection type : Shut down o/p voltage, re-power on to recover
; by internal RTH1 detect power transistor
Protection type : Shut down o/p voltage, re-power on to recover
By internal fuse open
Optional (Only type F) None
-10 ~ +40 @ 100% load, +60 @ 50% load℃℃
Compliance to FCC class A, EAC TP TC 020
Compliance to EAC TP TC 020
WORKING TEMP.
REMOTE CONTROL
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
SAFETY STANDARDS
-10 ~ +35 @ 100% load ; +60 @ 50% load℃℃
Open : Normal work ; Short : Remote off
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH non-condensing
o
Compliance to EN61000-4-2,3,8, EAC TP TC 020
Compliance to EN55032 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark, EAC TP TC 020
True sine wave output (THD<3%)
High surge power up to 400W
High efficiency up to 88%
Fanless design, cooling by free air convention
Built-in remote ON-OFF control
Front panel indicator for operation status
Power ON-OFF switch
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input reverse polarity / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
3 years warranty
RATED POWER 200W
OVER LOAD (Typ.)
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
Features :
OTHERS
PACKING
1.63Kg; 6pcs/10.8Kg/1.44CUFT
MTBF
DIMENSION
106.2K hrs min. MIL-HDBK-217F (25 )
205*158*59mm (L*W*H)
NOTE
1.Efficiency, AC regulation and THD are tested by 200W, linear load at 13V/26V/52V input voltage.
2.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting.
3.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V.→± →± →±
4.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
5.Type F for 60Hz only.
230W for 180 sec. / 300W for 10 sec. / surge power 400W for 30 cycles(typ.)
11.3 4%±
22.5 4%± 45 4%±45 4%±22.5 4%±
10.5 4%± 21 4%± 42 4%±42 4%±21 4%±
11.3 4%±
10.5 4%±
TS-200 series
File Name:TS-200-SPEC 2020-06-29
50 0.1Hz 50/60Hz selectable by setting button±
60 0.1Hz 50/60Hz selectable by setting button±
FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
24V 48V 24V 48V
BAT. VOLTAGE 12V12V
NO LOAD CURRENT DRAW (Typ.)
OFF MODE CURRENT DRAW 1mA
BATTERY TYPES
Open & sealed Lead Acid
200W True Sine Wave DC-AC Power Inverter
80 5℃± 80 5℃± 80 5℃± 80 5℃± 85 5℃±
AC VOLTAGE
100 / 110 / 115 / 120VAC selectable by setting button S.W
Factory setting set at 110VAC
200 / 220 / 230 / 240VAC selectable by setting button S.W
Factory setting set at 230VAC
FUNCTION
EMC IMMUNITY
EMC EMISSION
TS-200-112 TS-200-124 TS-200-148 TS-200-212 TS-200-224 TS-200-248
MODEL NO.
= A, F = B, C, D
E
13
TPTC004
IEC62368-1
(for 212/224/248 only)
EAC TP TC 004 approved, Design refer to
U 458L
IEC62368-1 CB, EAC TP TC 004 approved

Summary of content (2 pages)