TS-200/400 Inverter Instruction Manual
TS-200/400 Inverter Instruction Manual Index 1. Safety Guidelines ............................................................................... 1 2. Introduction ........................................................................................ 1 2.1 Features ......................................................................................... 1 2.2 Main Specification ........................................................................ 2 3. User Interface ....................................
1.Safety Guidelines (Please read through this manual before assembling TS200/400) Risk of electrical shock and energy hazard. All failures should be examined by a qualified technician. Please do not remove the case of the inverter by yourself! Please do not install the inverter in places with high moisture or near water. Please do not install the inverter in places with high ambient temperature, under direct sunlight or near flame source.
Remote ON/OFF control Complete protective features Output voltage / Frequency selectable Fully digital controlled Compliance to UL458 / FCC / E 13 / CE Can be used for most electronic products with AC input 3 years global warranty 2.2 Main Specification TS-200 Model Rated O power U T AC voltage P U T Waveform Protection Bat.
3. User Interface 3.1 Front Panel A AC output outlet: For application demands of different geographic areas all over the world, there are many different kinds of optional AC outlets to choose from. Receptacle types Area Type-A Type-B Type-C Type-D Type-E Type-F USA Europe Australia U.K. Japan GFCI B LED Indicating Panel: Shows inverter operating status. C Function Setting: Output voltage and frequency can be set through this button.
C C B Reverse Polarity Will Damage The Unit. ON _ _ D _ _ OFF Chassis Ground R.C E Reverse Polarity Will Damage The Unit. ON _ _ OFF B Chassis Ground R.C (TS-200) A E D (TS-400) A Figure 3.2: Rear Panel 4. TS-200/400 setup (Output Voltage & Frequency) 4.1 Initial State The initial states of the inverters are either 110Vac/60Hz or 230Vac/50Hz. If users need to revise it for certain application, it can be done using the setting button on the front panel (Please refer to section 4.2).
STEP 4: The LED will change state each time you press the setting button for 1 second and then release (refer to Figure 4.2). Please select the voltage that you need. 110Vac (220Vac) 115Vac (230Vac) 100Vac (200Vac) 120Vac (240Vac) Figure 4.2: State Circulation Diagram of Output Voltage STEP 5: After selecting the output voltage, press the setting button for 3~5 seconds and the inverter will send out a "Beep" sound. Voltage setting is now finalized and you may go on to the frequency setting.
WARNING: Please choose suitable batteries that are compatible with the rated input DC voltage of TS-200/400 (refer to spec). If the input DC voltage is too low (ex. using 12Vdc battery bank for 24Vdc input models), TS-200/400 will not started up. If the input DC voltage is too high (ex. using 48Vdc battery bank for 24Vdc input models), TS-200/400 could get damaged! 5.
(B) Suggested battery type and capacity Battery type Battery capacity Lead-acid battery 112 212 124 12V / 120Ah ~ 12V / 400Ah 224 24V / 60Ah ~ 24V / 200Ah 148 248 48V / 30Ah ~ 48V / 100Ah (C) Requirements for Installation TS-400 should be mounted on a flat surface or holding rack with suitable strength. In order to ensure the lifespan of the unit, please refrain from operating in environment of high dust or moisture.
(E) Example of system diagram As short as possible Larger than 15cm AC O/P LOAD TS-200/400 Larger than 15cm Battery DC I/P -+ - + Chassis Should less than 1.5m Wall or system FG (F) Derating 100 100 Others 80 LOAD (%) LOAD (%) 80 60 TS-200-1xx 50 40 20 -10 60 40 20 0 10 20 30 35 40 Ambient Temperature ( 50 60 10.5VDC 21VDC 42VDC ) 11.5VDC 23VDC 46VDC 15VDC (HORIZONTAL) 30VDC 60VDC Battery Input Voltage (V) Figure 6.2: Output Derating Curve Figure 6.
7. Failure Correction Notes TS-200/400 should be serviced by a professional technician. Any improper usage or modification may damage the unit or result in shock hazard. If you are not able to clear the failure condition, please contact. Status Possible Reasons Ways to Eliminate Abnormal input Check the DC input source. Make sure the voltage is within the required range. Over temperature protection Make sure that the ventilation is not blocked or the ambient temperature is too high.