Data Sheet

SPECIFICATION
20A
0.63A
21 ~ 30VDC
86%
75 5℃±
10A
0.32A
42 ~ 60VDC
87%
70 5℃±
20A
0.63A
21 ~ 30VDC
87.5%
75 5℃±
10A
0.32A
42 ~ 60VDC
88.5%
70 5℃±
AC VOLTAGE
MAXIMUM OUTPUT POWER
WAVEFORM
Note.2
OUTPUT
FREQUENCY
Note.6
AC REGULATION Note.2
VOLTAGE RANGE (Typ.) Note.3
EFFICIENCY (Typ.) Note.1
DC CURRENT (Typ.)
INPUT
INPUT
BATTERY
OUTPUT
ENVIRONMENT
FUSE
SAFETY &
EMC
BAT. LOW ALARM
BAT. LOW SHUTDOWN
OVER TEMPERATURE
OUTPUT SHORT
BAT. POLARITY
GFCI PROCTECTION
PROTECTION
PROTECTION
True sine wave (THD<3%)
40A
1.25A
10.5 ~ 15VDC
86%
85 5℃±
40A*2 40A*1 20A*1
20A*140A*1
±3.0% at rated input voltage
10.5 ~ 15VDC
84.5%
40A
1.25A
40A*2
85 5℃±
Protection type : Shut down o/p voltage, re-power on to recover
; by internal RTH1 detect power transistor
Protection type : Shut down o/p voltage, re-power on to recover
By internal fuse open
Optional (Only type F) None
Compliance to FCC class A
, EAC TP TC 020
Compliance to EAC TP TC 020
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
SAFETY STANDARDS
-10 ~ +40 @ 100% load ; +60 @ 50% load
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH non-condensing
o
Compliance to EN61000-4-2,3,8, EAC TP TC 020
Compliance to EN55032 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark, EAC TP TC 020
True sine wave output (THD<3%)
High surge power up to 800W
High efficiency up to 88.5%
Thermostatically controlled cooling fan
Built-in remote ON-OFF control
Front panel indicator for operation status
Power ON-OFF switch
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input reverse polarity / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
3 years warranty
RATED POWER 400W
OVER LOAD (Typ.)
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
Features :
OTHERS
PACKING
1.73Kg; 6pcs/11.4Kg/1.55CUFT
DIMENSION
205*158*67mm (L*W*H)
NOTE
1.Efficiency is tested by 300W, linear load at 13V/26V/52V input voltage.
2.AC regulation and THD are tested by 400W, linear load at 13V/26V/52V input voltage.
3.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V.
→± →± →±
4.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting.
5.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
6.Type F for 60Hz only.
460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.)
11.3 4%±
22.5 4%± 45 4%±45 4%±22.5 4%±
10.5 4%± 21 4%± 42 4%±42 4%±21 4%±
11.3 4%±
10.5 4%±
TS-400 series
File Name:TS-400-SPEC 2020-06-29
50 0.1Hz 50/60Hz selectable by setting button±
60 0.1Hz 50/60Hz selectable by setting button±
FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
24V 48V 24V 48V
BAT. VOLTAGE 12V12V
NO LOAD CURRENT DRAW (Typ.)
OFF MODE CURRENT DRAW 1mA
BATTERY TYPES
Open & sealed Lead Acid
400W True Sine Wave DC-AC Power Inverter
100 / 110 / 115 / 120VAC selectable by setting button S.W
Factory setting set at 110VAC
200 / 220 / 230 / 240VAC selectable by setting button S.W
Factory setting set at 230VAC
REMOTE CONTROL
Open : Normal work ; Short : Remote off
FUNCTION
MTBF
104.7K hrs min. MIL-HDBK-217F (25 )
EMC IMMUNITY
EMC EMISSION
TS-400-112 TS-400-124 TS-400-148 TS-400-212 TS-400-224 TS-400-248
MODEL NO.
= A, F = B, C, D
E
13
TPTC004
IEC62368-1
(for 212/224/248 only)
EAC TP TC 004 approved, Design refer to
U 458L
IEC62368-1 CB, EAC TP TC 004 approved

Summary of content (2 pages)