Data Sheet

SPECIFICATION
38A
21 ~ 30VDC
88%
19A
42 ~ 60VDC
89%
38A
21 ~ 30VDC
90%
19A
42 ~ 60VDC
91%
MAXIMUM OUTPUT POWER (Typ.)
WAVEFORM Note.6
OUTPUT FREQUENCY Note.8
AC REGULATION (Typ.)
VOLTAGE RANGE (Typ.)
Note.3,5
EFFICIENCY (Typ.) Note.1
DC CURRENT (Typ.)
INPUT
INPUT
BATTERY
OUTPUT
ENVIRONMENT
FUSE
SAFETY &
EMC
BAT. LOW ALARM
BAT. LOW SHUTDOWN
OVER TEMPERATURE
OUTPUT SHORT
BAT. POLARITY
GFCI PROCTECTION
PROTECTION
PROTECTION
True sine wave (THD<3%)
75A
10.5 ~ 15VDC
89%
40A*3 30A*2 20A*2
20A*230A*2
±3.0%
10.5 ~ 15VDC
86%
75A
40A*3
80 5℃±
Protection type : Shut down o/p voltage, re-power on to recover
; by internal RTH3 detect on heatsink of power diode
Protection type : Shut down o/p voltage, re-power on to recover
75 5℃±
By internal fuse open
Optional (Only type F) None
Compliance to FCC class A
, EAC TP TC 020
Compliance to EAC TP TC 020
WORKING TEMP. Note.4
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
SAFETY STANDARDS
0 ~ +40 @ 100% load ; +60 @ 50% load℃℃
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH non-condensing
o
EAC TP TC 004 approved, Design refer to
U 458L
Compliance to EN61000-4-2,3,8, EAC TP TC 020
Compliance to EN55032 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark, EAC TP TC 020
True sine wave output (THD<3%)
High surge power up to 1400W
High efficiency up to 91%
Power ON-OFF switch
Standby saving mode can be selectable
Front panel indicator for operation status
Built-in fan ON-OFF control function
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Reverse polarity / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
3 years warranty
RATED POWER (Typ.) 700W
OVER LOAD (Typ.)
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
Protection type : Shut down o/p voltage, re-power on to recover
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
AC O/P-FG , Bat I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
Features :
OTHERS
PACKING
3.8Kg
; 2pcs/8.6Kg/1.27CUFT
DIMENSION
295*184*70mm (L*W*H)
NOTE
1.Efficiency is tested by 530W, linear load at 13V, 26V, 52V input voltage.
2.All parameters not specified above are measured at rated load, 25 of ambient temperature and set to factory setting.
3.Input derating capacity referenced by curve 2.
4.Output derating capacity referenced by curve 1.
5.The tolerance of each voltage value by models is:112/212 0.5V;124/224 1V;148/248 2V.→± →± →±
6.THD is tested by 700W, linear load at 13,26,52V input voltage.
7.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
8.Type F for 60Hz only.
800W for 180 sec. / 1050W for 10 sec. / surge power 1400W for 30 cycles
11.3 4%±
22.5 4%± 45 4%±45 4%±22.5 4%±
10.5 4%± 21 4%± 42 4%±42 4%±
IEC62368-1 CB, EAC TP TC 004 approved
21 4%±
11.3 4%±
10.5 4%±
TS-700 series
File Name:TS-700-SPEC 2020-06-29
50 0.1Hz 50/60Hz selectable by setting button S.W±
60 0.1Hz 50/60Hz selectable by setting button S.W±
FRONT PANEL INDICATOR
SAVING MODE (Typ.)
Default disabled. Load 5W will be changed to standby mode
Battery voltage level, output load level, saving mode, fault and operation status
24V 48V 24V 48V
BAT. VOLTAGE 12V12V
NO LOAD DISSIPATION (Typ.)
6W @ standby saving mode
OFF MODE CURRENT DRAW 1mA
BATTERY TYPES
Open & sealed Lead Acid
700W True Sine Wave DC-AC Power Inverter
AC VOLTAGE
200 / 220 / 230 / 240VAC selectable by setting button S.W
100 / 110 / 115 / 120VAC selectable by setting button S.W
Factory setting set at 110VAC Factory setting set at 230VAC
MTBF
74.4K hrs min. MIL-HDBK-217F (25 )
EMC IMMUNITY
EMC EMISSION
TS-700-112 TS-700-124 TS-700-148 TS-700-212 TS-700-224 TS-700-248
MODEL NO.
= A, F = B, C, D
E
13
TPTC004
IEC62368-1
(for 212/224/248 only)

Summary of content (2 pages)