Datasheet
UL60950-1 approved; design refer to IEC60950-1,EN60950-1
Compliance to EN55022 (CISPR22) Class B,EN61000-3-2,EN61000-3-3
I/P-O/P:3.0KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level (surge 4KV), criteria A
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/ 70%RH25℃/
File Name:USP-150-SPEC 2014-03-27
150W
150W
151.2W
RATED POWER
151.2W
11.0~13.2V
13.5~16.5V
21.6~26.4V
VOLTAGE ADJ. RANGE
32.4~39.6V
110~160% rated output power
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
WORKING TEMP
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
2000ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
90 ~ 295VAC 127 ~ 417VDC
47 ~ 63Hz
2A/115VAC 1A/230VAC 0.7A/277VAC
Cold start 65A/230VAC
<2mA / 240VAC
13.6 ~ 16.3V
17 ~ 21V
26.7 ~ 32.4V
Shut down o/p voltage, recovers automatically after temperature goes down
-30 ~ +65℃ (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 60℃)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
216.3K hrs min. MIL-HDBK-217F (25℃)
215*67.4*33mm (L*W*H)
91.5%
16ms/230VAC 16ms/115VAC at full load
91.5%
93%
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±2.0%
±2.0%
±2.0%
100mVp-p
150mVp-p
150mVp-p
12V
12.5A
0 ~ 12.5A
15V
10A
0 ~ 10A
24V
6.3A
0 ~ 6.3A
USP-150-12
USP-150-15
USP-150-24
150W U-Bracket Single Output with PFC Function
■ Features :
USP-150 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
WITHSTAND VOLTAGE Note.6
ISOLATION RESISTANCE
CURRENT RANGE
41.4 ~ 48.6V
93%
±1.0%
±0.5%
±2.0%
250mVp-p
36V
4.2A
0 ~ 4.2A
USP-150-36
153.6W
43.2~52.8V
53 ~ 64.8V
93%
±1.0%
±0.5%
±2.0%
250mVp-p
48V
3.2A
0 ~ 3.2A
USP-150-48
‧Universal AC input / Full range(up to 295VAC)
‧Built in active PFC function
‧Constant Voltage design
‧High efficiency up to 93%
‧Protections: Short circuit / Overload / Over voltage / Over temperature
‧Cooling by free air convection
‧U-bracket low profile:33mm
‧ZVS technology to reduce power dissipation
‧3 years warranty
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Please remove the component D1 before conducted Hipot test.
PF≧0.98/115VAC PF≧0.96/230VAC PF≧0.94/277VAC at full load
0.48kg; 24PCS/12.5kg/0.61CUFT
EMC IMMUNITY
EMC EMISSION