Datasheet

3
SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
2000ms,100ms/230VAC4000ms,100ms/115VACatfullload
12ms/230VAC
90~264VAC127~370VDC
47~63Hz
0.94/230VAC
4A/115VAC2A/230VAC
22A/115VAC44A/230VAC
<2mA /240VAC
105~120% ratedoutputpower
5.7~7V3.7~4.6V 13.5~16.3V
105~130%ratedoutputpower
17~21V 26.7~32.4V 53~64.8V
Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
80 5 (TSW1)detectonheatsinkofpowertransistor80 5 (TSW2)detectonheatsinkofpowerdiode
Protectiontype:Shutdowno/pvoltagewithauto-recovery
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
Complianceto EN61000-4-2,3,4,5,6,8,11;ENV50204,lightindustrylevel,criteria A
-10~+65 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~45
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
106.3Khrsmin.MIL-HDBK-217F(25 )
235.2*101.5*38mm(L*W*H)
1.1Kg;16pcs/18Kg/0.72CUFT
78% 88%84%
0.95/230VAC0.98/115VACatfullload
16ms/230VAC16ms/115VACatfullload
88% 88% 89%
1.0% 1.0% 1.0% 1.0%
0.5%0.5% 0.5% 0.5% 0.5% 0.5%
2.0%2.0%
2.0%2.0%
2.0% 2.0% 2.0% 2.0%
80mVp-p80mVp-p
4.5~5.5V2.97~3.6V
100mVp-p
10.8~13.2V
100mVp-p
13.5~16.5V
150mVp-p
21.6~26.4V
150mVp-p
43.2~52.8V
5V3.3V
70A70A
0~50A
0~70A
0~50A
0~70A
250W
350W
165W
231W
12V
29.2A
0~25A
0~29.2A
300W
350.4W
15V
23.4A
0~20A
0~23.4A
300W
351W
24V
14.6A
0~12.5A
0~14.6A
300W
350.4W
48V
7.3A
0~6.25A
0~7.3A
300W
350.4W
USP-350-5USP-350-3.3 USP-350-12 USP-350-15 USP-350-24 USP-350-48
FileName:USP-350-SPEC2010-10-18
350WSingleOutputwithPFCFunction
Universal AC input / Full range
Built in active PFC circuit compliance to EN61000-3-2
Protections: Short circuit / Overload / Over voltage / Over temperature
Free air convection for 300W and 350W with 23.5CFM forced air
High power density 6.3w/in
ZVS technology to reduce power dissipation
Active AC surge current limiting
U-bracket low profile:38mm
3 years warranty
Features :
USP-350 se ri es
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
EMICONDUCTION&RADIATION
CURRENTRANGE(23.5CFMFAN)
RATEDPOWER(convection)
CURRENTRANGE(convection)
RATEDPOWER (23.5CFMFAN)

Summary of content (2 pages)