Datasheet

SPECIFICATION
MODEL APV-12-5 APV-12-12 APV-12-15 APV-12-24
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
5V 12V 15V 24V
2A 1A 0.8A 0.5A
0 ~ 2A 0 ~ 1A 0 ~ 0.8A 0 ~ 0.5A
10W 12W 12W 12W
100mVp-p 120mVp-p 120mVp-p 150mVp-p
±5.0%
±1.0%
±2.0%
1500ms, 30ms / 230VAC 1500ms,30ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
76% 82% 82% 84%
5.75 ~ 6.75V 13.8 ~ 16V 17.5 ~ 21V 27.6 ~ 32.4V
0.2A/230VAC 0.35A/115VAC
COLD START 70A(twidth=120 s measured at 50% Ipeak) at 230VACμ
0.25mA / 240VAC
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
Protection type : Shut off o/p voltage, clamping by zener diode
12W Single Output Switching Power Supply
Constant voltage design
Universal AC input / Full range
Protections: Short circuit / Over load / Over voltage
Fully isolated plastic case
Cooling by free air convection
Small and compact size
Class power unit, no FG
Class 2 power unit
ass LPSP
IP30 design
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost, high reliability
2 years warranty
Features :
APV-12 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
20ms/230VAC 15ms/115VAC at full load
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
File Name:APV-12-SPEC 2014-09-22
EMC IMMUNITY
Compliance to EN55015,EN61000-3-2 Class A,EN61000-3-3
Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A
EMC EMISSION
77*40*29(L*W*H)
1145.7K hrs min. MIL-HDBK-217F (25 )
0.08Kg; 120pcs/11.8Kg/1.06CUFT
LPS
110
SELV
F
UL8750,CSA C22.2 No.250.0-08, ENEC EN61347-1,EN61347-2-13,EN62384 Independent,IP30 Approved
IP30
()Note.8