Datasheet
78.5%78.5%76% 78.5% 80%
80% 80.5%
SPECIFICATION
GS12E05-P1I GS12E07-P1I GS12E09-P1I GS12E12-P1I GS12E15-P1I GS12E18-P1I GS12E24-P1I
ORDERNO.
SAFETY MODEL NO.
DCVOLTAGE
RATEDCURRENT
OUTPUT
SETUP,RISE,HOLDUP TIME
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PLUG
CABLE
OVERLOAD
OVERVOLTAGE
9V7.5V5V 12V 15V 18V 24V
GS12E12 GS12E15 GS12E18 GS12E24
1.33A1.6A2.0A 1.0A 0.8A 0.67A 0.5A
CURRENTRANGE 0~1.33A0~1.6A0~2.0A 0~1.0A 0~0.8A 0~0.67A 0~0.5A
RIPPLE&NOISE(max.) Note.2 90mVp-p90mVp-p75mVp-p 120mVp-p 150mVp-p 180mVp-p 200mVp-p
VOLTAGETOLERANCE Note.3
LINEREGULATION Note.4
LOADREGULATION Note.5
3.0% 3.0%
1.0% 1.0% 1.0% 1.0% 1.0%
5.0%
4.0%
4.0%
5.0%
1.0% 1.0%
4.0%
4.0%
3.0%
3.0%
3.0%
3.0% 2.0% 2.0%
500ms,20ms,30ms/230VAC atfullload500ms,20ms,10ms/115VAC
90~264VAC135~370VDC
47~63Hz
0.31 A /230VACA /115VAC0.16
COLDSTART 25A /115VAC45A /230VAC
0.25mA /240VAC
>105%ratedoutputpower
115%~135%
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
1414.6Khrsmin.MIL-HDBK-217F (25 )
0~+50 (Referto"DeratingCurve")
20%~90%RHnon-condensing
-20~+85 ,10~95%RH
0.03%/ (0~40 )
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
65*47*26.5mm(L*W*H)
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Tolerance: includes set up tolerance, line regulation, load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.Load regulation is measured from 10% to 100% rated load.
6.The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification
provided by the IC manufacturer.
CONNECTOR
GS12E09
GS12E07
GS12E05
RATEDPOWER 12W 12W12W12W10W 12.06W 12W
StandardtypeP1I:2.1 *5.5 *9.5mmturningforktype,centerpositiveforstock;Othertypeavailablebycustomerrequested
StandardtypeUL11856ft(4FT onlyfor5Voutput)forstock;Othertypeavailablebycustomerrequested
Features :
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Clampbyzenerdiode
ENVIRONMENT
PROTECTION
U1 Tj140 typically(U1)DetectonmaincontrolIC
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
OVERTEMPERATURE Note.6
10~12W AC-DCSingleOutputWall-mountedtype
GS12E se ri es
Universal AC input / Full range
No load power consumption< 0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
2
Class power (without earth pin)
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: TUV / CB / CE
Pass LPS for full series
2 years warranty
pole EURO plug
TUVEN60950-1 approved
I/P-O/P:3KVAC
I/P-O/P: /25 /70%RH
100MOhms/500VDC
CompliancetoEN55022,EN61204-3,EN61000-3-2,3,FCCpart15classB
CompliancetoEN61000-4-2,3,4,5,6,8,11, l criteria AEN61204-3, ightindustrylevel,
PACKING
0.15Kg;100pcs/16Kg/CARTON
EMCIMMUNITY
EMCEMISSION
FileName:GS12E-SPEC2011-06-14