Datasheet
SPECIFICATION
ORDERNO.
SAFETY MODEL NO.
DCVOLTAGE Note.2
RATEDCURRENT
CURRENTRANGE
RATEDPOWER (max.)
RIPPLE&NOISE(max.) Note.3
OUTPUT
SETUP,RISE,HOLDUP TIME
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT
INPUT
ENVIRONMENT
INRUSHCURRENT(max.)
LEAKAGECURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note.7)
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V 7.5V 9V 12V 15V 18V 24V 28V 48V
GS18E05 GS18E07 GS18E09 GS18E12 GS18E15 GS18E18 GS18E24 GS
18E28 GS18E48
3.0A 2.0A 2.0A 1.50A 1.20A 1.0A 0.75A 0.64A 0.375A
0~3.0A 0~2.0A 0~2.0A
0~1.50A
0~1.20A 0~1.0A 0~0.75A
50mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p 150mVp-p 180mVp-
p 240mVp-p 240mVp-p
VOLTAGETOLERANCE Note.4
LINEREGULATION Note.5
LOADREGULATION Note.6
5.0% 5.0% 5.0% 3.0% 3.0%
3.0% 2.0% 2.0% 2.0%
1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
5.0% 5.0% 5.0% 3.0%
3.0% 3.0% 2.0% 2.0% 2.0%
90~264VAC135~370VDC
47~63Hz
0.5A /100VAC
45A /230VAC
0.25mA /240VAC
TUVEN60950-1approved
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:4242VDC
I/P-O/P:100MOhms/500VDC /25 /70%RH
500Khrsmin.MIL-HDBK-217F(25 )
0~+50 (Referto"DeratingCurve")
20%~90%RHnon-condensing
-20~+85 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
79*54*33mm(L*W*H)
210g;60pcs/13.5kg/CARTON
CONNECTOR
PLUG
CABLE
Seepage2
Seepage2
15W 15W 18W 18W 18W 18W 18W 18W
0~0.64A
18W
0~0.375A
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
Features :
CompliancetoEN55022, EN61000-3-2,3
CompliancetoEN61000-4-2,3,4,5,6,8,11,lightindustrylevel,criteria A
OVERLOAD
OVERVOLTAGE
110~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
105~135%ratedoutputvoltage
Protectiontype:Clampbyzenerdiode,outputshort
Universal AC input / Full range
No load power consumption<0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 pole EURO plug
Class power (without earth pin)
Protections: Short circuit / Over load / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: TUV / CB / CE
Pass LPS
2 years warranty
500ms,20ms,50ms/230VAC atfullload500ms,20ms,15ms/115VAC
FileName:GS18E-SPEC2011-06-14
15~18W AC-DCSingleOutputWall-mountedtype
GS18E s er ie s
79.5% 82% 83% 85% 85% 85% 86% 86.5% 87%
GS18E05-P1J GS18E09-P1J GS18E15-P1J GS18E24-P1J GS18E48-P1JGS18E07-P1J GS18E12-P1J GS18E18-P1J GS18E28-P1J
EMCIMMUNITY
EMCEMISSION