Datasheet
3 stage charging characteristic
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protection: Short circuit / Overload / Over voltage / Over temperature
2 color LED loading indicator
Low cost, high reliability
2 years warranty
Built-in cooling Fan ON-OFF control
Built-in remote ON-OFF control
Features :
PB-230-12
MODEL
BOOSTCHARGEVOLTAGE
FLOATCHARGEVOLTAGE
OUTPUTCURRENT
BATTERY TYPE
RECOMMENDEDBATTERY
CAPACITY(AMP HOURS)(Note5)
OUTPUT
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
OVERLOAD
OVERVOLTAGE
PROTECTION
ACCURRENT (Typ.)
14.4V
13.6V
16A
Open&SealedLead Acid
50~160Ah
90~264VAC127~370VDC
47~63Hz
81.5%
3A/115VAC1.5A/230VAC
COLDSTART 50A
<3.5mA /240VAC
90~110%ratedoutputcurrent
16~18V
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Protectiontype: Shutdowno/pvoltage,re-powerontorecover
Protectiontype: Automaticallyderatechargecurrentuntilzero
UL1012(forPB-230-xxAD1only), TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024,lightindustrylevel,criteria A
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
-20~+50 (Referto"DeratingCurve")
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
MTBF
244.5Khrsmin.MIL-HDBK-217F(25 )
190*96*49mm(L*W*H)
DIMENSIONOTHERS
NOTE
PACKING
1.21Kg;12pcs/15.5Kg/1.29CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
FUNCTION
REMOTECONTROL (CN105)
FANCONTROL
TEMPERATURESENSE
Open:NormalworkShort:StopCharging
RTH3 50 FanON, 45 FanOFF(Typ.)
ByNTC
PB-230-24 PB-230-48
28.8V 57.6V
27.2V 54.4V
8A 4A
24~80Ah 12~40Ah
85.5% 86%
31~35V 59~64V
FileName:PB-230-SPEC2011-08-18
ORDERNO. OUTPUTCONNECTOR SAFETY
PB-230-xx(standardmodel) 4pinpowerdin TUV/CE
PB-230-xxAD1(optionalmodel)
PB-230-xx xx=12,24,48; =Blank, AD1
Andersonconnector UL
POWERFACTOR(Typ.) PF>0.95/230VACPF>0.98/115VACatfullload
TUV
Rhe inl and
Pro duc tSafe ty
geprUfre
Sicherheit
( for PB-230-xxAD1 only)
CONNECTOR
PLUG
CABLE
Seepage2 thertypeavailablebycustomerrequested;O
Seepage2 thertypeavailablebycustomerrequested;O
230WSingleOutputBatteryCharger
PB-230 series
SPECIFICATION
EMCIMMUNITY
EMCEMISSION