User manual

3
Pin No. Function
Description
5,6
9,10
7,8
RY15
RC-/RC+
GND/RTH
Relay contact rating (max.): 30V/1A. "Short" when the unit is working
Turn the output ON and OFF by electrical or dry contact between
Temperature sensor which comes with the charger can be connected
normally; “Open” when the unit is in a faulty condition
pin10 (RC+) and pin9 (RC-). Open: start charging. Short: stop charging.
to the unit to allow temperature compensation of the charging voltage.
If the temperature sensor is not used, the charger can still work
normally.
5.LED Indication
Status
Color
Red
Orange
Green
Steady
Fail
Full Charging
Charging
Flashing
Types of failure:
1
5
2 3
4
Battery disconnected
Activation of protection function (e.g. OTP, OVP, and Short)
Damaged battery Reverse polarity
Incorrect battery voltage (e.g. PB-600-12 connected to 24V battery)
6.Explanation of operation logic (charging stages):
PB-600 has a total of 3 charg in g modes to choose from, 2 sta ges, 3 stages, and
8 stages. 8 stages charging differ from 2 stages with the addition of pulse, soft start,
analysis, recondition, float, and maintain stages. 2 stages provide simple and quick
charging. 3 stages is similar to 2 stages with the exception of not shutting OFF after
the battery is fully charged. Lastly, 8 stages will allow charging to maximum capacity.
User can select between 2,3 or 8 stages depending on their requirement.
6.1 2 stage charging (flick switch to "2" stage)
During initial charge (stage 1), charger will provide maximum current to the battery.
The built-in fan will also turn ON. As the battery starts to get full, charging current
will gradually decrease (stage 2). When charging current decrease to less than
10% of max. LED indicator will turn Green to show a full charge and the charger
will turn OFF.
Charge Current
Constant Current
stage 1 stage 2
Constant Voltage
Battery Full
Start
Charge Voltage
100%
10%
Orange Green
Color of LED
boost
V