Datasheet

SPECIFICATION
PD-45A PD-45B
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
ACCURRENT (Typ.)
5V 12V
CH2
5V
CH1
24V
CH2
3.2A 2A 3.2A 1.2A
0.4~5A 0.2~2.5A 0.4~5A 0.2~1.8A
40W 44.8W
Ratedoutputpowerforconvection;52Wwith18CFMmin.Forcedair
50mVp-p 120mVp-p 150mVp-p50mVp-p
CH1:4.75~5.5V CH1:4.75~5.5V
4.0% 7.0% 7.0%4.0%
1.0% 2.0% 2.0%1.0%
3.0% 4.0% 4.0%3.0%
800ms,20msatfullload
60msatfullload
90~264VAC127~370VDC
47~440Hz
77% 78%
1A/115VAC0.7A/230VAC
COLDSTART 15A/115VAC30A/230VAC
<0.75mA
53~75W ratedoutputpower
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved.
-10~+60
(Referto"DeratingCurve")
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.04%/ (0~50 )on+5Voutput
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
288.1Khrsmin.MIL-HDBK-217F(25 )
127*76*28mm(L*W*H)
0.2Kg;72pcs/16Kg/1.35CUFT
FileName:PD-45-SPEC 2011-08-18
5.75~6.75VDConCH1
OVERVOLTAGE
SAFETY STANDARDS
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
Complianceto EN55024,lightindustrylevel,criteria AEN61000-4-2,3,4,5,6,8,11,
45WDualOutputSwitchingPowerSupply
Features :
PD-45 se ri es
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
6. Heat Sink HS1,HS2 can not be shorted.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Universal AC input/Full range
Low leakage current<0.5mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
OUTPUTPOWER(max.)
UL60950-1, TUVEN60950-1approved
CH1
OUTPUTNUMBER
EMCIMMUNITY
EMCEMISSION