Datasheet
RCP s e ri e s
Function
AC-OK
AC-NG
DC-OK
DC-NG
T-OK
T-ALARM
LED
ON
OFF
ON
OFF
----
----
Description
Wheninputvoltage 82V 4V
Wheninputvoltage 82V 4V
Whenoutputvoltage 80% 5%ofVorated.
Whenoutputvoltage 80% 5%ofVorated.
Whentheinternaltemperature(TSW1& TSW2short)iswithinsafelimit
Whentheinternaltemperature(TSW1or TSW2open)exceedsthelimitoftemperaturealarm
4.FrontPanelIndicators&CorrespondingSignalatFunctionPins
5.ICBusInterfaceOption
5.1 Addressing(A0,A1,A2)
TheDIP switchdownpositionislogiclevel"1"andtheuppositionislevel"0". AddressareapplicablewhenmodulesRCP-1000ICfunctionareused.
Addressdipswitchsetting
ON
1 2
Module A ModuleB ModuleC
3 4 5 6 7 8 9
OFF
2
2
Signal
0~0.5V
4.5~5.5V
0~0.5V
4.5~5.5V
0~0.5V
4.5~5.5V
PSUOutput
ON
OFF
ON
ON
ON
OFF
*
*Signalbetweenfunctionpinand"-S".
3.3RCP-1000-48
90
92
94
96
98
100
Vout(%)
1.3M 1.7M 2.4M 3.6M 7.6M NC
R1( )
min.0.1W
100
102
104
106
108
110
Vout(%)
NC 345K 140K 70K 36K 15K
R2( )
min.0.1W
A2
3
6
9
A1
2
5
8
A0
1
4
7
Module
A
B
C
1000~3000WFrontEndPowerSystem
FileName:RCP series-SPEC2011-12-19
3.2RCP-1000-24
90
92
94
96
98
100
Vout(%)
560K 750K 1M 1.6M 3.3M NC
R1( )
min.0.1W
100
102
104
106
108
110
Vout(%)
NC 330K 130K 62K 30K 10K
R2( )
min.0.1W