SPECIFICATION
MODEL RD-35A RD-35B RD-3513
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
Note.4
LOAD REGULATION Note.5
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
5V 12V
CH2
5V
CH1
13.5V
CH1
24V
CH2
-13.5V
CH2
4A 1A 2.2A 1.3A1A 1.3A
0.3 ~ 4A 0.2 ~ 1A 0.3 ~ 4A 0.3 ~ 2A0.2 ~ 1.3A 0.2 ~ 1.5A
32W 35W 35.1W
80mVp-p 120mVp-p 80mVp-p 120mVp-p120mVp-p 120mVp-p
CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 11.5 ~ 15.5V
±2.0% ±6.0% ±2.0% ±4.0%±5.0% ±4.0%
±0.5% ±1.5% ±0.5% ±0.5%±1.0% ±0.5%
±0.5% ±3.0% ±0.5% ±3.0%±2.0% ±3.0%
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
80ms/230VAC 16ms/115VAC at full load
88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
47 ~ 63Hz
79% 82% 80%
CH1: 16.87 ~ 19.57V
CH1: 5.75 ~ 6.75V
0.8A/115VAC 0.55A/230VAC
COLD START 36A/230VAC
<2mA / 240VAC
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
UL60950, TUV EN60950 approved
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
-25 ~ +70 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )on CH1 output
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
179Khrs min. MIL-HDBK-217F (25 )℃
File Name:RD-35-SPEC 2011-08-19
Protection type : Hiccup mode, recovers automatically after fault condition is removed
99*82*36mm (L*W*H)
0.3Kg; 45pcs/14Kg/0.83CUFT
35W Dual Output Switching Power Supply
RD-35 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
ENVIRONMENT
SAFETY &
EMC
(Note 6)
PROTECTION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105℃ long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70℃
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
■
Features :
CH1
OUTPUT NUMBER
EMC IMMUNITY
EMC EMISSION