Datasheet
Immunity to Environmental Conditions
EN45545-2 Fire Test Conditions
Test method
Items
Test Items
Cooling Test
R22
R24
R25
R26
Oxygen index test
Smoke density test
Smoke toxicity test
Oxygen index test
Glow-wire test
Vertical flame test
Dry Heat Test
Damp Heat Test, Cyclic
Vibration Test
Increased Vibration Test
Shock Test
Low Temperature Storage Test
Standard
Standard
EN 50155 section 12.2.3 (Column 2, Cl ass TX)
EN 60068-2-1
EN 45545-2:2013
EN ISO 4589-2:1996
EN 45545-2:2013
EN ISO 5659-2:2006
EN 45545-2:2013
NF X70-100:2006
EN 45545-2:2013
EN ISO 4589-2:1996
EN 45545-2:2013
EN 60695-2-11:2000
EN 45545-2:2013
EN 60695-11:2003
Temperature: -40℃
Dwell Time: 2 hrs/cycle
Temperature: 25 ~55℃ ℃
Humidity: 90%~100% RH
Duration: 48 hrs
Temperature: 19℃
Humidity: 65%
Duration: 10 mins
Temperature: 19℃
Humidity: 65%
Duration: 5 hrs
Temperature: 21 3± ℃
Humidity: 65 5% ±
Duration: 30ms*18
Temperature: -40℃
Dwell Time: 16 hrs
Temperature: 70 / 85℃ ℃
Duration: 6 hrs / 10min
EN 50155 section 12.2.5
EN 60068-2-30
EN 50155 section 12.2.11
EN 61373
EN 50155 section 12.2.11
EN 61373
EN 50155 section 12.2.11
EN 61373
EN 50155 section 12.2.3 (Column 2, Cl ass TX)
EN 60068-2-1
EN 50155 section 12.2.4 (Column 2, Cl ass TX)
EN 50155 section 12.2.4 (Column 3, Cl ass TX & Column 4, Class TX)
EN 60068-2-2
Test conditions
Hazard Level
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
HL1 HL2 HL3
Status
No damage
PASS
PASS
PASS
PASS
PASS
PASS
Salt Mist Test
Temperature: 35 2℃± ℃
Duration: 96 hrs
EN 50155 section 12.2.10 (Class ST4)
PASS