Datasheet

Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC Fan
Built-in fan ON / OFF control
LED indicator for power on
Fixed switching frequency at 90KHz
3 years warranty
SPECIFICATION
SP-240-5 SP-240-7.5 SP-240-12 SP-240-15 SP-240-24 SP-240-30 SP-240-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
RIPPLE&NOISE(max.) Note.2
OUTPUT VOLTAGE ADJ.RANGE
VOLTAGETOLERANCE Note.3
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSHCURRENT (Typ.)
ACCURRENT(Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
SAFETY &
FUNCTION
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
FANCONTROL
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
PROTECTION
5V 7.5V 12V 15V 24V 30V 48V
45A
32A 20A 16A 10A 8A 5A
0~45A 0~32A 0~20A 0~16A 0~10A 0~8A 0~5A
225W 240W 240W 240W 240W 240W 240W
150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p
4~6V 6~9V 10~14V 12~18V 20~28V 27~33V 41~56V
2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.3% 0.3%
0.2% 0.2% 0.2%
1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5%
800ms,50ms/230VAC1500ms,50ms/115VACatfullload
20ms/230VAC20ms/115VACatfullload
88~264VAC124~370VDC
47~63Hz
PF>0.95/230VACPF>0.98/115VACatfullload
79%
3.6A/115VAC1.8A/230VAC
83%
9.4~10.9V
14.7~17.5V
19~22.5V
29.5~35V
57.6~67.2V
34.7~41V
86% 86% 87% 89%88%
25A/115VAC40A/230VAC
<2mA /240VAC
105~135%ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
6.3~7.5V
90 5 (5V,7.5V),85 5 (12V,15V,24V,30V,48V)(TSW1:detectonheatsinkofpowertransistor)
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024,lightindustrylevel,criteria A
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
-20~+70 (Referto"DeratingCurve")
RTH2 40 FANON, 35 FANOFF(Typ.)
20~90%RHnon-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
284Khrsmin.MIL-HDBK-217F(25 )
190*93*50mm(L*W*H)
0.8Kg;18pcs/15.4Kg/1.04CUFT
Features :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
FileName:SP-240-SPEC2011-08-23
SP-240 se ri es
240WSingleOutputwithPFCFunction
EMCIMMUNITY
EMCEMISSION