Single-Carrier Cabinets Up to three Single-Carrier Cabinets (SCC1) can be stacked to form
a single PN. Refer to the following figure.
Single-Carrier Cabinets come in any of four configurations:
A basic control cabinet that contains a TN2404 processor, tone clock, and a power
converter
An expansion control cabinet that contains additional port circuit packs, interfaces to the
PPN, a maintenance interface, and a power converter
A duplicated control cabinet that contains the same equipment as the basic control
cabinet
A port cabinet that contains port circuit packs and a power converter
Typical Single-Carrier Cabinet (SCC1)
Multi-Carrier Cabinets A Multi-Carrier Cabinet (MCC1) is a 70 in. (178 cm) cabinet that has
up to five carriers. See the following figure for an example of an MCC1. The following are the
three types of Multi-Carrier Cabinets:
A PPN cabinet that contains the ports, SPE, an interface to an EPN cabinet, and/or a
CSS.
An EPN cabinet that contains additional ports, interfaces to the PPN and other EPN
cabinets, the maintenance interface, optional interfaces to other EPN cabinets, a switch
node (in an SN in a CSS-connected system), or an ATM switch.
An Auxiliary cabinet that contains that is equipment used for optional, system-related
hardware, such as rack-mount equipment.