INSTALLATION GUIDE CCT/WATTAGE ADJUSTABLE LED PANEL
TABLE OF CONTENTS Safety Information ...........................................................2 Pre-Installation ................................................................. Specifications ............................................................... Drawing Dimensions................................................... Mounting Options ....................................................... Mounting Kit ......................... Tools Required .......................................................
PRE-INSTALLATION Specifications Voltage Dimming 0-10V Operating Temperature Range -20 Ceiling Type T-bar Light Source Non-replaceable LED 50˚C 22 ceiling Drawing Dimensions 11.81 in. (30.30 cm) 47.75 in. (121.30 cm) 1.57 in. (4.0 cm) 2x2 23.74 in. (60.30 cm) 23.74 in. (60.30 cm) 1.57 in. (4.0 cm) 2x4 23.74 in. (60.30 cm) 47.75 in. (121.30 cm) 1.57 in. (4.
PRE-INSTALLATION (CONTINUED) Mounting Options Recessed Surface (requires Mounting Kit) Suspension (requires Mounting Kit) Mounting Kit SKU SKU DESCRIPTION DESCRIPTION DP-PKT-12-S DP-SMF-14-W 1’X4’ SURFACE MOUNT KIT DP-PKT-14-S DP-SMF-22-W 2’X2’ SURFACE MOUNT KIT DP-SMF-24-W 2’X4’ SURFACE MOUNT KIT Tools Required Safety goggles Phillips screwdriver Drill Flathead screwdriver Ladder Wire cutters Hardware Included AA - Wire nuts x5 Before You Begin Turn off the electricity at the circuit
INSTALLATION OPTION 1 - STANDARD RECESSED MOUNT WARNING: Before you begin, turn the power off at the circuit breaker or fuse box to avoid electric shock. 1 Remove the a. Remove the grid tile from the ceiling. 2 Connect the wires a. Lift the fixture to the ceiling. b. Follow the steps in the Make the Electrical Connections section of 3 Select CCT and Wattage a. CCT adjustment 3500/4000/5000K CCT (pre-set to 4000K).
MAKING THE ELECTRICAL CONNECTIONS WARNING: Before you begin, turn the power off at the circuit breaker or fuse box to avoid electric shock. 1 Open the junction box 1 a. Unscrew and remove the junction box cover (1) from the fixture. 2 Connect the supply wires Connect the green ground wire from the fixture to the supply ground wire. Connect the white wire from the fixture to the supply white wire (neutral wire). Connect the black wire from the fixture to the supply black wire (live wire).
MAKING THE ELECTRICAL CONNECTIONS (CONTINUED) 3 Connect the dimming wires Connect the purple wire from the fixture to the purple (DIM+) supply wire. Secure the two connections using two wire nuts (AA). AA Wrap the two wire connections with electrical tape for a more secure connection . tape 4 Reinstall the junction a. Position the wires back inside 1 b. Reinstall the junction box cover (1). Secure with screw.
OPTION 2: SURFACE MOUNT INSTALLATION SKU DESCRIPTION DP-SMF-14-W 1’X4’ SURFACE MOUNT KIT DP-SMF-22-W 2’X2’ SURFACE MOUNT KIT DP-SMF-24-W 2’X4’ SURFACE MOUNT KIT (Available for 1’x4’, 2’x2’ and 2’x4’) Parts List Quantity 1’x4’ 2’x2’ Image 2’x4’ Size Material 0.04 inches diamete r, 0.40 inches length Zinc Coated I ron 0.16 inches diamete r, 0.98 inches length Zinc Coated I ron 0.24 inches diamete r, 1.18 inches length PVC 24.08 inches length, 2.44 inches height Aluminum 48.
OPTION 3: SUSPENSION MOUNT INSTALLATION SKU DISCRIPTION DP-PKT-12-S DP-PKT-14-S Parts List Suspension Hook Quantity 2’x2’ Image 2’x4’ Size D P-P K T-12 C ABLE 0.16 inches diamete r, 0.98 inches length Zinc Coated I ron 0.24 inches diamete r, 1.18 inches length PVC 0.59 inches diamete r, 0.67 inches height Nickel Plated Copper 0.45 inches diamete r Zinc Coated I ron See Cable Images 3.28 foot main cable, 2.30 foot branch cable Stainless See Cable Images 0.35 inches diamete r, 1.
GUÍA DE INSTALACIÓN
Índice Información de seguridad..............................................2 Antes de la instalación....................................................3 Especificaciones ..........................................................3 Dimensiones ................................................................3 Opciones de montaje .................................................4 Kits de montaje............................................................4 Herramientas requeridas..............................
Antes de la instalación Especificaciones Voltaje Atenuación Rango de temperatura -20 50˚C 22 Tipo de cielo raso Fuente de luz LED no reemplazable Dimensiones 1x4 11.81 pulg. (30.30 cm) 47.75 pulg. (121.30 cm) 1.57 pulg. (4.0 cm) 2x2 23.74 pulg. (60.30 cm) 23.74 pulg. (60.30 cm) 1.57 pulg. (4.0 cm) 2x4 23.74 pulg. (60.30 cm) 47.75 pulg. (121.30 cm) 1.57 pulg. (4.
• • •
2 3 250 350 0LM 0K/4 CCT ADJ 4 000 K/50 00K 3500K/4000K/5000K 2500LM/3750LM/4500LM /375 0LM /450 0LM WATT ADJ
1 1 2 AA
3 AA 4 1
3.9’ 0.
INSTALLATION GUIDE CCT/PANNEAU À LEDS RÉGLABLE EN PUISSANCE
Table des matières Consignes de sécurité ....................................................2 Avant l’installation ...........................................................3 Caractéristiques techniques ......................................3 Dimensions du croquis ...............................................3 Options de montage ..................................................4 Kits de montage ..........................................................4 Outils requis ...................................
Avant l’installation Caractéristiques techniques Tension Gradation 0-10V Éventail de température -20 Type de plafond Plafond en T-barre exposé Source lumineuse LED non remplaçable 50˚C 22 Dimensions du croquis 1x4 11,81 po. (30,30 cm) 47,75 po. (121,30 cm) 1,57 po. (4,0 cm) 2x2 23,74 po. (60,30 cm) 23,74 po. (60,30 cm) 1,57 po. (4,0 cm) 2x4 23,74 po. (60,30 cm) 47,75 po. (121,30 cm) 1,57 po.
PRÉ-INSTALLATION (SUITE) Options de montage En retrait Surface (nécessite un kit de montage) Suspension (nécessite un kit de montage) Accessoires du kit de montage KITS DE MONTAGE DE SUSPENSION SKU KITS DE MONTAGE EN SURFACE DESCRIPTION SKU DESCRIPTION DP-PKT-12-S KIT DE MONTAGE DE 2 CÂBLES DE SUSPENSION (DE 0,6 À 3,9 po DE LONGUEUR) DP-SMF-14-W KIT DE MONTAGE EN SURFACE 1'x4' DP-PKT-14-S DP-SMF-22-W KIT DE MONTAGE EN SURFACE 2'x2' KIT DE MONTAGE DE 4 CÂBLES DE SUSPENSION (DE 0,6 À 3,9 po DE
OPTION D'INSTALLATION 1 - SUPPORT ENCASTRÉ STANDARD AVERTISSEMENT: Avant de commencer, coupez le courant au niveau du disjoncteur ou de la boîte à fusibles pour éviter tout choc électrique. 1 Retirez le panneau de plafond a. Retirez la dalle de grille du plafond 2 Connecter les fils a. Soulevez l'équipement au plafond b. Suivez les étapes de la section "Effectuer les connexions électriques" de ce manuel 3 Sélectionnez CCT et Wattage a.
RÉALISER LES CONNEXIONS ÉLECTRIQUES AVERTISSEMENT: Avant de commencer, coupez le courant au niveau du disjoncteur ou de la boîte à fusibles pour éviter tout choc électrique. 1 Ouvrez la boîte de jonction 1 a. Dévissez et retirez le couvercle de la boîte de jonction (1) de l'appareil.
EFFECTUER LES CONNEXIONS ÉLECTRIQUES (SUITE) 3 Connecter les fils de gradation Connectez le fil violet de l'appareil au fil d'alimentation violet (DIM+). AA Fixez les deux connexions à l'aide des deux écrous de fil restants (AA). Enveloppez les deux connexions de fil avec du ruban électrique pour une connexion plus sûre (ruban électrique non inclus). 4 Réinstaller le couvercle de la boîte de jonction a. Replacez les fils à l'intérieur b. Réinstallez le couvercle de la boîte de jonction (1).
OPTION 2 : INSTALLATION EN SURFACE Nécessite un kit d'accessoires KITS DE MONTAGE EN SURFACE SKU DESCRIPTION DP-SMF-14-W 1’X4’ SURFACE MOUNT KIT DP-SMF-22-W 2’X2’ SURFACE MOUNT KIT DP-SMF-24-W 2’X4’ SURFACE MOUNT KIT LE KIT COMPREND : (Disponible pour 1'x4', 2'x2' et 2'x4') Liste des pièces Quantité 1’x4’ 2’x2’ Image 2’x4’ Taille Matériel Vis A 0,04 pouces de diamètre, 0,40 pouces de longueur Fer zingué Fer enduit de zinc Vis B 0,16 pouces de diamètre, 0,98 pouces de longueur Fer zingué
OPTION 3 : INSTALLATION SUR SUPPORT SUSPENDU Nécessite un kit d'accessoires SKU DESCRIPTION DP-PKT-12-S KIT DE MONTAGE DE 2 CÂBLES DE SUSPENSION (DE 0,6 À 3,9 po DE LONGUEUR) DP-PKT-14-S KIT DE MONTAGE DE 4 CÂBLES DE SUSPENSION (DE 0,6 À 3,9 po DE LONGUEUR) LE KIT COMPREND: (Tous les kits sont compatibles avec les panneaux Dream de toutes tailles) Liste des pièces Quantité Image 2’x2’ 2’x4’ Taille IMAGES DE CÂBLE Matériel CÂBLE DP-PKT-12 Vis B (KA 4x25) 0,16 pouces de diamètre, 0,98 pouces d