Congratulations Congratulations on your new MEDQUIP for many occasions.
Table of Contents Congratulations ....................................................................................................................... Indication for Use .................................................................................................................... Important Safeguards ............................................................................................................. ● DANGER ..................................................................................
● Breastfeeding Tips ....................................................................................................................... Troubleshooting ....................................................................................................................... ● Interruption of Electrical Service ...................................................................................................... ● Radio Frequency Energy ......................................................................
Important Safeguards The MEDQUIP Breast Pump is designed for a single user and should never be shared or resold; doing so will void the warranty. READ ALL INSTRUCTIONS BEFORE USING DANGER: To reduce the risk of electrocution: ● Always unplug this product immediately after using. ● Do not use while bathing. ● Do not place or store this product where it can fall or be pulled into a tub or sink. ● Do not place or drop into water or other liquid.
Important Safeguards (Continued) ● Make sure the voltage of the AC/DC Adapter is compatible with the power source. ● Plug the AC/DC Adapter into the electrical outlet first, then plug the Power Cord into your MEDQUIP Electric Breast Pump. ● MEDQUIP has provided an AC/DC Adapter and/or Li-Ion battery pack with this device. Using any other AC/DC Adapter or Li-Ion battery pack not approved by the manufacturer voids the warranty.
Parts Guide AC/DC Adapter Vacuum Tubing with Adapter Breast Pump Main Unit Bottle Adapter Kit Expression Collection Combo Kit English 5
Parts Guide ● Electrical Pump Main Unit TOP VIEW BOTTOM VIEW T1 T2 T3 T4 LED Screen Vacuum Adjusting Wheel Expression Button Power Button Battery Cover Tubing Adapter Inlet AC/DC Adapter Inlet English 6
Parts Guide ● Expression Collection Combo Kit Cap Diaphragm Electric-pump Diaphragm Kit Cup with O-Ring Breastshield Body One-Way Valve Bottle Adapter Collection Bottle Bottle Base English 7 Expression Collection Kit
How to Assemble the Expression Collection Kit Your MEDQUIP Breast Pump comes pre-assembled; however, you will need to re-assemble it after each cleaning. (For cleaning instructions, see page 21) Below is a step-by-step guide for assembling the Expression Collection Kit: 1. Hold the "horn" of the Breastshield Body in one hand. Make sure the bottle-thread side opening is facing up. 2.
How to Assemble the Expression Collection Kit (Continued) 3. With your thumb and forefinger, gently seal any openings on the tip of the One-Way Valve and shape into a straight line. Note: This is critical to the performance of the Pump. 4. Carefully twist on the Bottle Adapter to the Breastshield Body for a secure fit. Note: Be sure not to bump the One-Way Valve when twisting the Breastshield Body & the Bottle Adapter pieces together. If you bump the One-Way Valve, repeat step 3.
How to Assemble the Expression Collection Kit (Continued) 5. With the Bottle Adapter in one hand, twist on the Collection Bottle for a secure fit.
How to Assemble Electric-pump Diaphragm Kit 1. With the Cup in one hand, place the Diaphragm in the Cup (matching the shape of the Cup). Press around the edges of the Diaphragm for a secure fit. Make sure the Diaphragm is evenly mounted on the Cup and there is no gap in between them. 2. Place the Cap on the Cup & Diaphragm. (Be sure to align the hinge and hinge cover.) Press tightly to seal.
How to Assemble the Expression Collection Combo Kit 1. With the O-Ring side down, put the Electric Pump Diaphragm Kit into the top of the Breastshield Body opening. Twist the ElectricPump Diaphragm Kit clockwise into the Breastshield Body until it locks into place. Turn Clockwise 2. Take the open-end of Vacuum Tubing (the end without the adapter) and connect to the Tubing Connector located on the Cap. Push together firmly for a tight seal. Note: Make sure there is no moisture in the Tubing.
How to Assemble the Expression Collection Combo Kit (Continued) 3. Make sure the Tubing Connector is properly inserted into the Tubing Adapter Inlet on the Electric Pump Main Unit.
Power Options Your Breast Pump may be operated under any of the following power supply modes: Using your AC/DC Adapter (included): ● Electrical safety can only be achieved when using the AC/DC Adapter which was provided with the Pump. Use of any another Adapters causes concern for the safety of the product and/or the user and voids the warranty. 1. Plug the AC/DC Adapter into an electrical outlet. 2. Attach the Power Cord to the AC/DC Adapter Inlet on the Electric Pump Main Unit.
Using 4 AA Alkaline Batteries (not included): AA Battery Compartment 4 AA Batteries (not included) ● Always replace all 4 AA Batteries at the same time. ● Remove all batteries from the Electric Pump Main Unit if the Pump is not going to be used for extended periods of time. ● Properly dispose of all batteries, according to government regulations for environmental protection and recycling. Note: Alkaline Batteries may present a risk of fire or chemical burn if mistreated. Do NOT disassemble any battery.
Install the Batteries(AA Alkaline): 1. Open the Battery Cover. 2. Remove the old batteries if you are replacing them.
Install the Batteries AA Alkaline (Continued): 3. Insert 4 new AA Alkaline Batteries. Note: Make sure the polarity is correct as indicated. 4. Close the Battery Cover, making sure it "snaps" into place.
Pumping Instructions 1. Hold the Expression Collection Kit to your breast so that your nipple is centered inside the Breastshield. Note: Please check for correct fitting of the shield. 2. Press the Power Button to begin pumping.
Pumping Instructions (Continued) 3. Start pumping with T1 speed. T1 LED on Top panel lights up. 4. If you prefer a different pumping speed, just press the Expression Button to switch between 4 different speed modes. Suction speed gradually slows down from T1 to T4. Note: The Expression suction speed is switched in following sequence: T1 -> T2 -> T3 -> T4 ->T3 -> T2 ->T1.
Pumping Instructions (Continued) 5. Adjust the suction to your comfort level by rolling the Vacuum Adjusting Wheel. The current Level is shown with the number marked on the Vacuum Adjusting Wheel. The suction power gradually increases from 1 to 7. 6. When your pumping session is finished, turn the Pump off by pressing the Power Button . Note: Make sure there is no suction on the nipples before removing the Breastshield.
Cleaning Instructions Unless otherwise instructed by your healthcare provider, follow these sanitizing and cleaning instructions. Sanitize Prior to First Use: Before you use your MEDQUIP Breast Pump for the first time, disassemble and boil all parts of the Expression Collection Combo Kit in water for 10 minutes. ● Be sure to use enough water to keep all parts afloat while boiling. ● Do NOT boil Tubing or Tubing Adapter. ● Remove all parts from the water immediately after sterilizing.
Cleaning Instructions (Continued) ● Do NOT use solvents or abrasives. ● Rinse with hot, clean water. ● To clean the Electric Pump Main Unit, wipe it with a wet wipe or damp cloth, using only water or water mixed with a mild soap. Tubing Cleaning Instructions: ● Wipe the outside of the Tubing with a clean, damp cloth. Avoid getting water or other fluids inside the Tubing. ● If liquids are found inside Tubing, rinse the Tubing with clean hot water. Hang to AIR DRY COMPLETELY BEFORE USING.
Breastmilk Storage Guidelines Check with your healthcare provider or an International Board Certified Lactation Consultant for specific storage instructions. This information is based on current research and applies to mothers who have healthy, full-term babies who are storing their milk for home use. Important Notes: ● STORAGE CONTAINERS: The best option for storing human milk is glass or hard-sided plastic containers with well-fitting tops.
Breastmilk Storage Guidelines (Continued) Place Refrigerator Temperature How long Things to know 39°F or colder ● Up to 72 hours is best. ● Up to 5-8 days is okay for very clean expressed milk. Store milk in the back of the main body of the refrigerator. 0°F or colder ● Up to 6 months is best. ● Up to 12 months is okay. Store milk toward the back of the freezer where temperature is most constant.
Tips Pumping Tips: The most important and successful part of pumping is the let-down reflex. The let-down reflex is when your milk begins to flow freely. ● Try relaxing with a warm, wet compress on your breasts. ● Drink plenty of fluids. ● Avoid outside distractions. ● Visualize yourself happy, well rested and successful at pumping. ● Sometimes a light circular massaging of the breasts prior to and/or during a pumping session will help your let-down reflex start/continue.
Tips (Continued) Battery Storage: ● When storing the battery for a short period of time, store within the following temperature range: -4°F to 140°F (-20°C to 60°C). ● When storing the battery for an extended period of time, store within the following temperature range: 32°F to 77°F (0°C to 25°C).
Troubleshooting Interruption of Electrical Service: If you experience an interruption of electrical service, due to a power surge or other factors, during normal operation of Breast Pump, try the following: your MEDQUIP ● Unplug the AC/DC Adapter cord from the electrical outlet and wait for five seconds before plugging the AC/DC Adapter cord back into the electrical outlet. ● Try a different electrical outlet in another room or on a different circuit.
Troubleshooting (Continued) No response while operate Adjusting Wheel and Mode button: You CANNOT adjust the suction level or switch between Swift Expression and Natural Expression while in My Favorite Pattern. If you have to, stop My Favorite Pattern by pressing the M Button.
Technical Data Power Requirements: ● AC/DC Adapter (included) North American Plug configuration: Brand: Acute Ideas Model:MLF-012W1201000, 100V ~ 240V AC, 50/60 Hz, 0.4A, wall plug type AC/DC Adapter with DC 12V/1A output. ● Batteries: 4 AA Batteries; 1.5V Alkaline Technical Specifications: VACUUM: T1 phase:-177mmHg(-23.6kpa) T2 phase:-216mmHg(-28.9kpa) T3 phase:-240mmHg(-32kpa) T4 phase:-250mmHg(-33.
Warranty Limited Consumer Product Warranty (United States) Breast Pump is warranted to the original consumer "the purchaser" to be free from defects This MEDQUIP in material and workmanship which are not commercially acceptable for the period of one year from the date of purchase on the pump mechanism and a period of 120 days on all other components. Warranty coverage terminates if you sell or otherwise transfer this product to another person.
Warranty (Continued) If you wish to make a claim under this warranty, you will need the following: ● The entire original MEDQUIP product ● The original receipt showing date of purchase ● Return Authorization Number (RA#) ● Detailed description of the problem You, the purchaser, are responsible for all shipping charges. Do NOT send product without a RA#. To obtain a RA# and shipping address: Please contact MEDQUIP Customer Service Department by; Toll-Free: (888) 404-5666 Tel: (843)815-5301 Web: www.medquip.